3)Patterning of the PCB
■
Input and output pattern should be the same width and length.
■
Voltage drop from the output terminal to remote sensing point must be less than 0.2V.
■
ESR from the slave of the output terminal to remote sensing point must be 10mΩ or less
■
Parallel operation should be separated Vin line of each BRxS(Fig 10.2.2)
■
The beat noise reduction of parallel operation, it is effective to put the input CH(Fig 10.2.3)
Fig. 10.2.2
Patterning of the PCB
(a) BRxS40
(b) Other models
Fig. 10.2.3
Beat noise reduction
BRFS/BRDS 10-2
Separate
Vin pattern
Connected
Vin pattern
Must be
0.1uH pattern
or parts
0.1uH
pattern or parts
<Recommend>
<Deprecated>
Applications manual
For BRFS/BRDS series