12
Bedienungs- und Montageanleitung für Cosidrum/ Operating and assembly instructions built in burners / manuel de montage et mode démploi
Cosi fires
User and installation instructions associated with collection: Cosidrum
Contents of this document
1.
Important safety instructions
pag.2
2.
Assembly instructions
pag. 4
3.
User manual
pag. 8
4.
Specification cosi fires
pag. 10
1. Important safety instructions according Cosidrum
In case of use of the Cosidrum these safety instructions should always be followed to reduce the risk of fire and
other damage to people and property. Read these safety instructions carefully before the Cosidrum is put into
operation.
1.
According to the mounting instructions the Cosidrum must always fitted correctly. The Cosidrum should
be placed straight on a hard, stable surface.
2.
Use only the type of gas and the type of cylinder specified in these instructions.
3.
The device must be placed far away from flammable materials (min. 2 meters) and the area around the
appliance must be clear of combustible materials and/or liquids.
4.
Before use, check if all connections to the cylinder are properly fitted and not loose,
c
heck that the
regulator seal is correctly fitted and able to fulfil its function. If the connections are loose, make sure
everything is fixed and tied before use. Make sure that the gas is turned off while fixing.
5.
Change the gas cylinder in a amply ventilated area, away from any ignition source (candle, cigarettes,
other flame producing appliances).
6.
Every time the gas connection is re-connected or at least once per month, the gas connection and hose
must be monitored for leaks. The tubing or the flexible hose must be changed within the prescribed
intervals. See chapter 2.5.
7.
The hose must never come into contact with the hot surface of the burner.
8.
The hose must comply with the national laws and regulations (EN 16436). The hose is connected to the
supplied gas pressure regulator. Do not connect the gas cylinder directly to the appliance without
regulator.
9.
The pressure regulator is set for 28-30mbar, 37mbar or 50mbar, and the regulator outlet pressure is 28-
30mbar, 37mbar or 50mbar. The gas regulator has to be set according to specific gas category (see on
data plate). The regulator should comply with EN 16129 standard.
10.
Never change the air valve settings of the burner . If the air vents of the fire rings are choking , turn right
into a gas technical specialist .
11.
In the event of gas leakage, the appliance shall not be used or if alight, the gas supply shall be shut off
and the appliance shall be investigated and rectified before it is used again.
12.
Never obstruct the free flow of air and oxygen to the device . Never change anything to the gas -
technical system of this unit . Any change to the system can be dangerous and will void any warranty on
the device .
13.
The injector in this appliance is not removeable and the injector in this appliance is only assembled by
manufacturer.
14.
This appliance is forbidden to convert from one gaspressure to another gaspressure.
15.
Keep children and pets away from the unit more than sufficient . The Cosidrum has components which
become very hot when in use. Wait after use until the appliance has cooled down before children and
pets come with the device in the vicinity . We recommend a minimum of 1.5 hours to wait .
16.
Never move the Cosidrum if the device is in use . Wait at least 1.5 hours after use before moving it.
Shut
off the valve at the gas cylinder or the regulator before moving the appliance.
17.
Never leave the Cosidrum during use without supervision
18.
The device has an open fire , make sure that during use of the Cosidrum there will always be supervision