8
5.8 - Programming the heating times
Using key KM and subsequently key K4 (>>), page 2 of the menus is accessed.
Using key K1 (PROG), the programming menu is selected.
Having selected this menu, it is possible to make one of the following choices:
· RIS (HEATING timer)
· SAN (DOMESTIC HOT WATER timer)
If the PROGR SAN parameter set (see section 5.9), does not anticipate the management of the SAN timer
(different to 2), one directly accesses the programming of just the timer for the heating.
- press key K1 (RIS), one accesses the menu for programming the heating timer;
- press key K1 (GIO) in order to set the day one intends to programme (pressing it repeatedly, one will see that the
two letters corresponding to the day of the week change continually, updating the day);
- press key K2 (IMP) to access the menu for selecting the temperature raising or lowering bands, comprising the
levels T0, T1 and T2 plus the choice which makes it possible to leave the value unchanged ( - - );
- choose the T0, T1 or T2 temperature level which one intends to set, the display automatically returns to the
previous status;
- using the keys K+ e K-, set the hour for that day during which one wishes it to function in the set timeband; (the
timebands T0, T1 and T2 are displayed on the histogram bar, respectively by means of: nil, a small black square
at the base of the histogram, two small black squares overlapping);
- press key K2 (IMP) once again to select the new temperature timeband and repeat the previous operation in
order to set the operating timeband under T1;
- repeat the above procedure, so as to set the operating timeband under T2.
So as to shift from one part of the timer to another over 24 hours, without changing the setting made previously,
proceed as follows:
- press key K2 (IMP), then press key K1 (- -); the display returns to the clock display, thus move between the
hours using the keys K+ e K- until reaching the desired time;
- repeat the above procedure, selecting a new T0, T1 or T2 temperature level.
Once the programming of the day has been carried out, just press key K3 (COP) in order to copy the same
programming to the next day, then press key K1 (GIO) in order to select the following day (whose time will have the
same programming made above), then press K3 (COP) once again so as to copy the programming to the next
day, and so on for all the days of the week which one wishes to programme as the same as the others. In order to
programme one day of the week differently, it is sufficient to do so as per the above indications, without it being
copied from a previous day.
In order to save the programme set, just press key KM. The display will return to normal view. If the display shows
the histogram bar 11 as per figure 3, it means that the programme set above is already active. If this is not so,
follow the instructions in section 5.2 to activate it.
5.8.1 - Calling up an existing programme for heating
The remote control makes 5 pre-compiled programmes available, in order to facilitate the user when programming
the time. Proceed as follows to access them:
- press key KM and subsequently key K4 (>>), page 2 of the menus is accessed;
- press key K1 (PROG), the programming menu is selected;
Once this menu has been selected, it is possible to make one of the following choices:
· RIS (HEATING timer)
· SAN (DOMESTIC HOT WATER timer)
If the PROGR SAN parameter set (see section 5.9) does not envisage the management of the SAN timer (different
to 2), one directly accesses the programming of just the timer for the heating.
- press key K1 (RIS), one accesses the menu for programming the heating timer;
- press key K4 (PRE), one accesses the menu for selecting the pre-set operating programme;
- press keys K+ o K- to select the pre-set programme nearest to one’s requirements;
- press key K1 (OK) in order to load the programme in the memory or press key K2 (ANNULLA) to return to the
previous menu without loading any pre-set programme.
Once the programme has been loaded, the display returns to show the menu of the heating programming mode.