background image

3

If you smell gas

l

 Close the gas cock.

l

 Ventilate the room.

l

 Do not use any electrical appliances, telephone

included.

l

  Immediately call a qualified technician or the gas

board from another room or building. If you cannot
contact them, call the Fire Brigade.

If you smell product of the combustion

l

 Switch off the appliance.

l

 Ventilate the room.

l

 Call a qualified technician.

In the presence of water leaks

l

 Switch off the appliance.

l

 Close the central water mains cock.

l

 Call a qualified technician.

Explosive or easily inflammable products
Do not store or use explosive or easily inflammable
materials such as paper, solvents, paints, etc..., in
the same room as the boiler.

In the event of a breakdown
In the event of breakdown and/or malfunctioning of the
appliance, disconnect it, do not attempt to repair it or
intervene in any way whatsoever. Contact a qualified
technician.

Qualified technicians
Qualified technicians are personnel with specific,
technical training in the heating system component
sector and with regards to domestic hot water
production for public use, fuel gas systems and
electrical systems. These individuals must have the
legally required qualifications.

1 - GENERAL SAFETY WARNINGS

F

This booklet forms an integral and essential

part of the product and must be carefully  kept
by the user, for  any future consultation. Ensure
that this booklet
  is handed over to the new
owners and/or installer if the appliance should
change hands or be moved for any reason
whatsoever.

F

The installation, setting and modification of

the gas appliance must be carried out by
qualified technicians, in compliance with local
and national norms and the instructions in the
installation and maintenance manual.

F

Flue pipes must not be modified in any way.

F

The user, in accordance with these instructions,

must keep the appliance in satisfactory running
order and ensure reliable, safe operating.

F

The user is responsible for employing a

qualified technician to carry out maintenance
work on the appliance in compliance with local
and national norms and the matters stated in
the installation and maintenance manual. We
highly recommend arranging a regular
maintenance contract with a qualified
technician.

F

The manufacturer cannot be held responsible

for any damage to people, animals or property
caused by inadequate maintenance.

F

Do not obstruct the ends of the venting pipes .

F

The technician will explain the functioning,

use of the appliance and use of the system to
the user.

F

The user must be familiar with filling and

discharge procedures for the boiler, and the
control and eventual adjustment of water
pressure in the heating circuit.

F

The user must be familiar with the

procedures for fully optimizing the
conservation of energy and avoiding waste
of the entire heating system.

F

Regularly check the system pressure using

the pressure gauge “13” (see figure 1) to
ensure a reading between 1 and 1.5 bar.

F

Wait a few minutes after opening the gas

supply cock before starting the boiler up.

F

Do not leave the boiler switched on

unnecessarily if it is not going to be used for
long periods; in such situations, close the gas
cock and disconnect from the electricity
mains supply. Consult section 3.16 if there is
a risk of freezing.

F

Do not touch the flue gas discharge pipe,

during and for some time after operations, as
it is very hot.

Summary of Contents for NOVADENS 24

Page 1: ...ADENS 24 24B NOVADENS 24C 24P NOVADENS 34 34B NOVADENS 34C 34P NOVADENS 45A 45C USERS MANUAL FOR GAS BOILERS PLEASE READ THE MANUAL CAREFULLY IT CONTAINS IMPORTANT INFORMATION REGARDING SAFETY INSTALLATION USE AND MAINTENANCE OF THE APPLIANCE ...

Page 2: ...mer mode 7 3 8 Winter mode 7 3 9 Adjusting the heating temperature 7 3 10 Adjusting the heating temperature with climatic adjustment 7 3 11 Domestic hot water temperature adjustment 8 3 12 Room temperature adjustment 8 3 13 Errors and alarms 8 3 14 Pressure gauge 8 3 15 Shutdown procedure 9 3 16 Precautions against freezing 9 3 17 Flue gas discharge 9 3 18 Operating anomalies 9 3 19 Remote control...

Page 3: ...carried out by qualified technicians in compliance with local and national norms and the instructions in the installation and maintenance manual FFlue pipes must not be modified in any way FThe user in accordance with these instructions must keep the appliance in satisfactory running order and ensure reliable safe operating FThe user is responsible for employing a qualified technician to carry out...

Page 4: ...OSMOGAS srl Via L da Vinci 16 47014 Meldola FC ITALY Tel 39 0543 498383 Fax 39 0543 498393 www cosmogas com info cosmogas com 2 4 Key to symbols used General danger Failure to observe this warning may compromise the smooth running of the appliance or cause serious damage to individuals animals or property l Operation symbol F Important indication symbol 2 5 Warranty See section 4 NOVADENS XXYYYY B...

Page 5: ...enu see section 3 6 During functioning display 1 of figure 1 displays the status of the boiler and display 2 see figure 1 shows the value of the parameter The various operating statuses are shown in the table in figure 2 Within the Users Menu see section 3 6 it is possible to check the last lock outs or errors which have occurred In addition to the operating modes the instrument panel provides imp...

Page 6: ...e lasting two minutes This is indicated by the appearance of on the display l wait two minutes until the end of the auto purging cycle l turn knob 7 of figure 1 until it reaches the heating temperature desired Turn knob 11 of figure 1 until it reaches the domestic water temperature desired The flame control appliance will start up the burner If the burner fails to ignite within 5 seconds the boile...

Page 7: ...ds the water to the system at the temperature set using knob 7 of figure 1 When the temperature inside the boiler reaches the temperature set the burner starts to modulate the flame so as to reduce the output to a minimum If the temperature rises further the burner shuts down Simultaneously the pump which sends the water to the system is switched on and off by the room thermostat This can be noted...

Page 8: ...aving this is a devicecapableofswitchingonandoffand or raising and lowering the room temperature in relation to certain set times Contact a qualified technician for the installation of this device This boiler is suitable for being connected to devices of this type 3 13 Errors and alarms The boiler control device carries out numerous checks When it detects a malfunction it shuts down the appliance ...

Page 9: ...is absolutely forbidden to introduce chemical additives such as anti freeze or others into the domestic water circuit 3 17 Flue gas discharge Due to its high efficiency and low pollution levels this boiler is considered to be ecological Therefore white smoke may be discharged from the discharge pipe under specific atmospheric and operating conditions There is no cause for alarm as it is only steam...

Page 10: ...e present on the remote control and have the following meaning green light on heating service on and correct communication between boiler and remote control green light blinking every 7 seconds correct communication between boiler and remote control red light on boiler in lock out status It is possible to re activate it by pressing the RESET key see figure 6 detail B If the lock out occurs frequen...

Page 11: ...manual or can be found in the Yellow Pages under Gas boilers l The technician will collect the warranty certificate and forward it to COSMOGAS 4 3 Warranty limits The warranty is invalid if the appliance is not installed by qualified technicians if the appliance is not installed in compliance with COSMOGAS instructions and or those established by national and or local standards in force the runnin...

Page 12: ...tenance manual and follow national and or local standards in force with the following results POSITIVE q NEGATIVE q SERVICE CENTRE Stamp Comments________________________________________________________________________ ___________________________________________________________________________________ Service Centre signature _________________________ User signature _________________________ WARRAN...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...COSMOGAS s r l Via L da Vinci 16 47014 MELDOLA FC ITALY info cosmogas com www cosmogas com ...