3 - USE

Figure 1 - Instrument panel

3.1 - Check that the
cocks are open

- The gas cock must be open;
- any supply and return valves must be
open;
- any hot and cold water valves must be
open.

3.2 - Check heating
system pressure

If the pressure inside the heating circuit
falls below  0.5 bar, the appliance
switches off and the display 1 as per

figure 1, shows 

 to indicate

that it is necessary to restore the correct
pressure. Proceed as follows:

l

open the filling cock (see figure 5)
turning it in a counter-clockwise
direction;

l

check the pressure on the pressure
gauge “13” of figure 1,  it must reach a
pressure of 1.5 bar and the indication

 must disappear;

l

close the filling cock (see figure 5)
turning it in a clockwise direction.

CAUTION!!! During normal

operations, the filling cock (see
figure 5) must always remain in the
closed position.

If, with time, the pressure drops, restore
the correct value. This operation may
have to be repeated several times
during the first month of operations to
remove any gas bubbles present.

3.3 - Overview

The boiler is pre-set with standard
parameters. However, it is possible to
make a number of changes or consult
the parameters by means of using the
“Users’ Menu” (see section 3.6).
During functioning display “1” of figure 1
displays the status of the boiler and
display  “2” (see figure 1) shows the

value of the parameter. The various
operating statuses are shown in the
table in figure  2.
Within the “Users’ Menu” (see section
3.6) it is possible to check the last
lock-outs or errors which have occurred.
In addition to the operating modes, the
instrument panel provides important
information on the current functioning of
the boiler, via the indicators “3”, “4”, “5”
and “6” of figure 1. In particular:
- the indicator “3” displays whether the
burner is functioning (on) or whether it is
off (blinking);
- the indicator “4” displays whether the
domestic hot water service is on or off;
- the indicator “6” displays whether a
heating service request is active (on) or
nor (off).

  1 - Parameter display.
  2 - Display of values adopted by parameters.
  3 - Burner status indicator. On = burner on, flashing = burner off.
  4 - Domestic hot water service status indicator. On = d.h.w. on, Off = d.h.w. off.
  5 - Indicator of decimal of value displayed.
  6 - Heating service status indicator. On = heating on, Off = heating off.
  7 - Heating temperature and start control.
  8 - Key for decreasing parameter values.
  9 - Key for resetting shutdowns and for scrolling the list of parameters.
10 - Key for increasing parameter values.
11 - Domestic hot water temperature and start control.
12 - On/off power switch.
13 - Heating circuit pressure gauge.

Summary of Contents for NOVADENS 24

Page 1: ...ADENS 24 24B NOVADENS 24C 24P NOVADENS 34 34B NOVADENS 34C 34P NOVADENS 45A 45C USERS MANUAL FOR GAS BOILERS PLEASE READ THE MANUAL CAREFULLY IT CONTAINS IMPORTANT INFORMATION REGARDING SAFETY INSTALLATION USE AND MAINTENANCE OF THE APPLIANCE ...

Page 2: ...mer mode 7 3 8 Winter mode 7 3 9 Adjusting the heating temperature 7 3 10 Adjusting the heating temperature with climatic adjustment 7 3 11 Domestic hot water temperature adjustment 8 3 12 Room temperature adjustment 8 3 13 Errors and alarms 8 3 14 Pressure gauge 8 3 15 Shutdown procedure 9 3 16 Precautions against freezing 9 3 17 Flue gas discharge 9 3 18 Operating anomalies 9 3 19 Remote control...

Page 3: ...carried out by qualified technicians in compliance with local and national norms and the instructions in the installation and maintenance manual FFlue pipes must not be modified in any way FThe user in accordance with these instructions must keep the appliance in satisfactory running order and ensure reliable safe operating FThe user is responsible for employing a qualified technician to carry out...

Page 4: ...OSMOGAS srl Via L da Vinci 16 47014 Meldola FC ITALY Tel 39 0543 498383 Fax 39 0543 498393 www cosmogas com info cosmogas com 2 4 Key to symbols used General danger Failure to observe this warning may compromise the smooth running of the appliance or cause serious damage to individuals animals or property l Operation symbol F Important indication symbol 2 5 Warranty See section 4 NOVADENS XXYYYY B...

Page 5: ...enu see section 3 6 During functioning display 1 of figure 1 displays the status of the boiler and display 2 see figure 1 shows the value of the parameter The various operating statuses are shown in the table in figure 2 Within the Users Menu see section 3 6 it is possible to check the last lock outs or errors which have occurred In addition to the operating modes the instrument panel provides imp...

Page 6: ...e lasting two minutes This is indicated by the appearance of on the display l wait two minutes until the end of the auto purging cycle l turn knob 7 of figure 1 until it reaches the heating temperature desired Turn knob 11 of figure 1 until it reaches the domestic water temperature desired The flame control appliance will start up the burner If the burner fails to ignite within 5 seconds the boile...

Page 7: ...ds the water to the system at the temperature set using knob 7 of figure 1 When the temperature inside the boiler reaches the temperature set the burner starts to modulate the flame so as to reduce the output to a minimum If the temperature rises further the burner shuts down Simultaneously the pump which sends the water to the system is switched on and off by the room thermostat This can be noted...

Page 8: ...aving this is a devicecapableofswitchingonandoffand or raising and lowering the room temperature in relation to certain set times Contact a qualified technician for the installation of this device This boiler is suitable for being connected to devices of this type 3 13 Errors and alarms The boiler control device carries out numerous checks When it detects a malfunction it shuts down the appliance ...

Page 9: ...is absolutely forbidden to introduce chemical additives such as anti freeze or others into the domestic water circuit 3 17 Flue gas discharge Due to its high efficiency and low pollution levels this boiler is considered to be ecological Therefore white smoke may be discharged from the discharge pipe under specific atmospheric and operating conditions There is no cause for alarm as it is only steam...

Page 10: ...e present on the remote control and have the following meaning green light on heating service on and correct communication between boiler and remote control green light blinking every 7 seconds correct communication between boiler and remote control red light on boiler in lock out status It is possible to re activate it by pressing the RESET key see figure 6 detail B If the lock out occurs frequen...

Page 11: ...manual or can be found in the Yellow Pages under Gas boilers l The technician will collect the warranty certificate and forward it to COSMOGAS 4 3 Warranty limits The warranty is invalid if the appliance is not installed by qualified technicians if the appliance is not installed in compliance with COSMOGAS instructions and or those established by national and or local standards in force the runnin...

Page 12: ...tenance manual and follow national and or local standards in force with the following results POSITIVE q NEGATIVE q SERVICE CENTRE Stamp Comments________________________________________________________________________ ___________________________________________________________________________________ Service Centre signature _________________________ User signature _________________________ WARRAN...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...COSMOGAS s r l Via L da Vinci 16 47014 MELDOLA FC ITALY info cosmogas com www cosmogas com ...

Reviews: