3 - USE

Figura 2 - Parameters displayed during functioning

PARAMETER    DESCRIPTION

ON DISPLAY “2” (figure 1)

Boiler on stand-by  or on hold (no heating or hot water request
exists)

Anti-freeze function active

Caution!!!  Domestic hot water active for more than 120 minutes
(turn domestic hot water to OFF position in order to reinstate
heating). Check that there are no leaking taps. If the problem
persists, contact a professionally qualified technician

Caution!!! System pressure too low, fill system follow section
3.2.

Domestic hot water service on

Heating service on

Boiler in lock-out mode. To reset it, press the 

 button

. If

the lock-out occurs frequently, contact a professionally qualified
technician.

Boiler fault. Contact a professionally qualified technician

Auto-purging procedure in progress . It will end within 2 minutes

Boiler temperature (°C)

Boiler temperature (°C)

Boiler temperature (°C)

No display

Domestic hot water temperature (°C)

Heating temperature (°C)

Lock-out code (see installation and
maintenance manual)

Error code (see installation and maintenance
manual)

Boiler temperature (°C)

POSSIBLE DISPLAYS

3.4 - Displays

During normal operations, the param-
eters’ display  “1” and the values’
display “2” (see figure 1) remain perma-
nently on  (if the ”Energy Saving” mode

has not be activated).
The parameters which can be displayed
are shown with their meaning in the
table shown in figure 2.

3.5 - Start-up
procedure

l

Open the gas cock;

l

switch on electric power to the boiler;

l

If the display shows code 

 21, it

means that the polarity has not been
observed between phase and neutral;

l

on initial start-up, the appliance carries
out an auto-purging cycle lasting two
minutes. This is indicated by the

appearance of 

 on the display;

l

wait two minutes until the end of the
auto-purging cycle;

l

turn knob “7” of figure 1 until it reaches
the heating temperature desired. Turn
knob “11” of figure 1 until it reaches the
domestic water temperature desired.

The flame control appliance will start-up
the burner.
If the burner fails to ignite within 5
seconds, the boiler will automatically
attempt ignition another three times, after
which if it fails to start-up, it will shut down

and the display will show 

 01.

Press the 

 button in order to re-set

normal operating conditions. The boiler will
automatically attempt another start-up.

CAUTION!!! If the appliance

frequently shuts down, contact a
qualified technician to restore normal
running conditions.
Now the boiler will continue to operate in
relation to the service requested and will
indicate the following on display “1”:

 if a domestic water request is active;

  if a heating request is active;

  if there is no domestic water or heating

request active.

3.6 - “Users’ menu”

Entry into the  “Users’ Menu” is shown
by display “1” blinking. In order to access

the “Users’ menu” just:

l

press the 

 button for 2 seconds

until the display starts to blink;

l

press and release the 

 button

several times until the parameter
desired is displayed;

l

by means of the 

 or 

 keys,

it is possible to change the value of
the parameter;

l

press 

  in order to confirm the

amended data and pass onto the next
parameter;

l

Once you have reached the end of the

menu, on the last 

, the display

“1” stops blinking indicating exit from
the “Users’ menu”.

If no key is pressed for more than 60
seconds, one automatically exists the
menu. Any change in the parameters not

confirmed using the  

 button, will

be lost.
In this menu it is possible to consult and/
or change the parameters indicated in
figure 3.

Summary of Contents for NOVADENS 24

Page 1: ...ADENS 24 24B NOVADENS 24C 24P NOVADENS 34 34B NOVADENS 34C 34P NOVADENS 45A 45C USERS MANUAL FOR GAS BOILERS PLEASE READ THE MANUAL CAREFULLY IT CONTAINS IMPORTANT INFORMATION REGARDING SAFETY INSTALLATION USE AND MAINTENANCE OF THE APPLIANCE ...

Page 2: ...mer mode 7 3 8 Winter mode 7 3 9 Adjusting the heating temperature 7 3 10 Adjusting the heating temperature with climatic adjustment 7 3 11 Domestic hot water temperature adjustment 8 3 12 Room temperature adjustment 8 3 13 Errors and alarms 8 3 14 Pressure gauge 8 3 15 Shutdown procedure 9 3 16 Precautions against freezing 9 3 17 Flue gas discharge 9 3 18 Operating anomalies 9 3 19 Remote control...

Page 3: ...carried out by qualified technicians in compliance with local and national norms and the instructions in the installation and maintenance manual FFlue pipes must not be modified in any way FThe user in accordance with these instructions must keep the appliance in satisfactory running order and ensure reliable safe operating FThe user is responsible for employing a qualified technician to carry out...

Page 4: ...OSMOGAS srl Via L da Vinci 16 47014 Meldola FC ITALY Tel 39 0543 498383 Fax 39 0543 498393 www cosmogas com info cosmogas com 2 4 Key to symbols used General danger Failure to observe this warning may compromise the smooth running of the appliance or cause serious damage to individuals animals or property l Operation symbol F Important indication symbol 2 5 Warranty See section 4 NOVADENS XXYYYY B...

Page 5: ...enu see section 3 6 During functioning display 1 of figure 1 displays the status of the boiler and display 2 see figure 1 shows the value of the parameter The various operating statuses are shown in the table in figure 2 Within the Users Menu see section 3 6 it is possible to check the last lock outs or errors which have occurred In addition to the operating modes the instrument panel provides imp...

Page 6: ...e lasting two minutes This is indicated by the appearance of on the display l wait two minutes until the end of the auto purging cycle l turn knob 7 of figure 1 until it reaches the heating temperature desired Turn knob 11 of figure 1 until it reaches the domestic water temperature desired The flame control appliance will start up the burner If the burner fails to ignite within 5 seconds the boile...

Page 7: ...ds the water to the system at the temperature set using knob 7 of figure 1 When the temperature inside the boiler reaches the temperature set the burner starts to modulate the flame so as to reduce the output to a minimum If the temperature rises further the burner shuts down Simultaneously the pump which sends the water to the system is switched on and off by the room thermostat This can be noted...

Page 8: ...aving this is a devicecapableofswitchingonandoffand or raising and lowering the room temperature in relation to certain set times Contact a qualified technician for the installation of this device This boiler is suitable for being connected to devices of this type 3 13 Errors and alarms The boiler control device carries out numerous checks When it detects a malfunction it shuts down the appliance ...

Page 9: ...is absolutely forbidden to introduce chemical additives such as anti freeze or others into the domestic water circuit 3 17 Flue gas discharge Due to its high efficiency and low pollution levels this boiler is considered to be ecological Therefore white smoke may be discharged from the discharge pipe under specific atmospheric and operating conditions There is no cause for alarm as it is only steam...

Page 10: ...e present on the remote control and have the following meaning green light on heating service on and correct communication between boiler and remote control green light blinking every 7 seconds correct communication between boiler and remote control red light on boiler in lock out status It is possible to re activate it by pressing the RESET key see figure 6 detail B If the lock out occurs frequen...

Page 11: ...manual or can be found in the Yellow Pages under Gas boilers l The technician will collect the warranty certificate and forward it to COSMOGAS 4 3 Warranty limits The warranty is invalid if the appliance is not installed by qualified technicians if the appliance is not installed in compliance with COSMOGAS instructions and or those established by national and or local standards in force the runnin...

Page 12: ...tenance manual and follow national and or local standards in force with the following results POSITIVE q NEGATIVE q SERVICE CENTRE Stamp Comments________________________________________________________________________ ___________________________________________________________________________________ Service Centre signature _________________________ User signature _________________________ WARRAN...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...COSMOGAS s r l Via L da Vinci 16 47014 MELDOLA FC ITALY info cosmogas com www cosmogas com ...

Reviews: