background image

7

3 - USE

Figure 3 - Parameters within the “Users’ Menu”

“USERS’ MENU”

Adjustment of the gradient of the line as per  figu-
re 4. Visible only with climatic adjustment active.
(See installation and instruction manual).

Adjustment of  “Minimum heating temperature”.
Visible only with climatic adjustment active. (See
installation and instruction manual).

Adjustment of “Maximum heating temperature”.
Visible only with climatic adjustment active. (See
installation and instruction manual).

Adjustment of the parallelism “b” of the line as per
figure 4. Visible only with climatic adjustment
active. (See installation and instruction manual).

Display of calculated heating temperature (if
climatic adjustment active) or display of tempera-
ture set via the control “7” as per figure 1.

Display of domestic hot water temperature set via
the control “11” as per figure 1.

Display of last error registered.

Display of last block which occurred.

Setting range: 0.1-5.0

Setting range: 20°C-60°C for radiant panels, 30°C - 60°C
for radiators.

Setting range: 45°C for radiant panels, 80°C for radiators.

Only display. The regulation is carried out using the control
“7” as per figure 1. It can adopt values ranging between -
10°C and +10°C

Only display. It can adopt values ranging between 20°C
and 80°C

Only display. It can adopt values ranging between 40°C
and 70°C

Only display. It can adopt the values indicated in the

installation and maintenance manual

Only display. It can adopt the values indicated in the

installation and maintenance manual

PARAMETER     DESCRIPTION

                                 INFORMATION ON DISPLAY “2”

3.7 - Summer mode

To disable the heating functions for a
prolonged period, leaving only the
domestic hot water function, switch the
heating temperature to minimum, until the
wording OFF appears, by turning knob  “7”
of figure 1.

3.8 - Winter mode

In Winter mode, by means of the pump ,
the boiler sends the water to the system
at the temperature set using knob “7” of
figure 1.
When the temperature inside the boiler
reaches the temperature set, the burner
starts to modulate the flame so as to
reduce the output to a minimum. If the
temperature rises further, the burner shuts
down.
Simultaneously, the pump which sends
the water to the system is switched on
and off by the room thermostat. This can
be noted, because indicator “6” of figure
1 switches on and off in correspondence

with the on and off of the pump.
At first the pump may make a noise. This
is due to the presence of residual air in
the hydraulic system which will soon
disappear on its own.
We recommend keeping the temperature
set using knob “7” at the point shown by
the symbols on the panel for a rational
use of the boiler. If it is a particularly cold
Winter and it is difficult to maintain the
desired temperature, turn knob “7” to
gradually higher values.

3.9 - Adjusting the
heating temperature

To set the heating temperature, turn
control knob “7” of figure 1. As soon as
the knob is touched, 

 will blink on

display and the temperature being set will
appear on display “2”. As a rule,  it is
sufficient to turn control knob “7” to the
half-way position. If it is a particularly cold
Winter, progressively increase the
temperature by rotating control “/”.

3.10 - Adjusting the
heating temperature
with climatic
adjustment

The adjustment of the heating
temperature, in the event that climatic
adjustment has been set, is carried out
by turning control  “7” as per figure 1. As
soon as the control is touched, display

“1” show a flashing 

 and display “2”

shows the value in °C of translation on a
parallel with the adjustment curve (see
figure 4, detail “b”. As a rule, it is sufficient
to adjust control “7” to the half-way
position. If the Winter is particularly rigid,
progressively increase the temperature
using control “7” until the temperature
inside the rooms is satisfactory. If the
comfort produced by the climatic
adjustment is not satisfactory (too hot,
too cold, room temperature not constant)

Summary of Contents for NOVADENS 24

Page 1: ...ADENS 24 24B NOVADENS 24C 24P NOVADENS 34 34B NOVADENS 34C 34P NOVADENS 45A 45C USERS MANUAL FOR GAS BOILERS PLEASE READ THE MANUAL CAREFULLY IT CONTAINS IMPORTANT INFORMATION REGARDING SAFETY INSTALLATION USE AND MAINTENANCE OF THE APPLIANCE ...

Page 2: ...mer mode 7 3 8 Winter mode 7 3 9 Adjusting the heating temperature 7 3 10 Adjusting the heating temperature with climatic adjustment 7 3 11 Domestic hot water temperature adjustment 8 3 12 Room temperature adjustment 8 3 13 Errors and alarms 8 3 14 Pressure gauge 8 3 15 Shutdown procedure 9 3 16 Precautions against freezing 9 3 17 Flue gas discharge 9 3 18 Operating anomalies 9 3 19 Remote control...

Page 3: ...carried out by qualified technicians in compliance with local and national norms and the instructions in the installation and maintenance manual FFlue pipes must not be modified in any way FThe user in accordance with these instructions must keep the appliance in satisfactory running order and ensure reliable safe operating FThe user is responsible for employing a qualified technician to carry out...

Page 4: ...OSMOGAS srl Via L da Vinci 16 47014 Meldola FC ITALY Tel 39 0543 498383 Fax 39 0543 498393 www cosmogas com info cosmogas com 2 4 Key to symbols used General danger Failure to observe this warning may compromise the smooth running of the appliance or cause serious damage to individuals animals or property l Operation symbol F Important indication symbol 2 5 Warranty See section 4 NOVADENS XXYYYY B...

Page 5: ...enu see section 3 6 During functioning display 1 of figure 1 displays the status of the boiler and display 2 see figure 1 shows the value of the parameter The various operating statuses are shown in the table in figure 2 Within the Users Menu see section 3 6 it is possible to check the last lock outs or errors which have occurred In addition to the operating modes the instrument panel provides imp...

Page 6: ...e lasting two minutes This is indicated by the appearance of on the display l wait two minutes until the end of the auto purging cycle l turn knob 7 of figure 1 until it reaches the heating temperature desired Turn knob 11 of figure 1 until it reaches the domestic water temperature desired The flame control appliance will start up the burner If the burner fails to ignite within 5 seconds the boile...

Page 7: ...ds the water to the system at the temperature set using knob 7 of figure 1 When the temperature inside the boiler reaches the temperature set the burner starts to modulate the flame so as to reduce the output to a minimum If the temperature rises further the burner shuts down Simultaneously the pump which sends the water to the system is switched on and off by the room thermostat This can be noted...

Page 8: ...aving this is a devicecapableofswitchingonandoffand or raising and lowering the room temperature in relation to certain set times Contact a qualified technician for the installation of this device This boiler is suitable for being connected to devices of this type 3 13 Errors and alarms The boiler control device carries out numerous checks When it detects a malfunction it shuts down the appliance ...

Page 9: ...is absolutely forbidden to introduce chemical additives such as anti freeze or others into the domestic water circuit 3 17 Flue gas discharge Due to its high efficiency and low pollution levels this boiler is considered to be ecological Therefore white smoke may be discharged from the discharge pipe under specific atmospheric and operating conditions There is no cause for alarm as it is only steam...

Page 10: ...e present on the remote control and have the following meaning green light on heating service on and correct communication between boiler and remote control green light blinking every 7 seconds correct communication between boiler and remote control red light on boiler in lock out status It is possible to re activate it by pressing the RESET key see figure 6 detail B If the lock out occurs frequen...

Page 11: ...manual or can be found in the Yellow Pages under Gas boilers l The technician will collect the warranty certificate and forward it to COSMOGAS 4 3 Warranty limits The warranty is invalid if the appliance is not installed by qualified technicians if the appliance is not installed in compliance with COSMOGAS instructions and or those established by national and or local standards in force the runnin...

Page 12: ...tenance manual and follow national and or local standards in force with the following results POSITIVE q NEGATIVE q SERVICE CENTRE Stamp Comments________________________________________________________________________ ___________________________________________________________________________________ Service Centre signature _________________________ User signature _________________________ WARRAN...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...COSMOGAS s r l Via L da Vinci 16 47014 MELDOLA FC ITALY info cosmogas com www cosmogas com ...

Reviews: