− 15 −
Operating Procedure
■
Data Logger Communications Screen
Take the following steps to read logging data.
In order to read data, a personal computer (see page 1) and Log Data Collection Set (optional item)
are required.
(1) Connect a USB cable to the USB connector on the bottom
of the Gas Detector.
(2) Press the MENU switch for three seconds while the gas
concentration screen is displayed to display the data logger
communications screen. Refer to page 11.
(3) When the MENU switch is pressed, OFF will stop flashing
and ON will start flashing. Data logger communication
with the PC will then be possible. Operate the PC for data
logger communication.
(4) When communication is finished, press the POWER switch
twice to return to the gas concentration screen.
(5) When finished, replace the gas detector into the case,
part No.3620584053, and zip it shut before entering the
hazardous location.
3. Operating Procedure (continued from previous page)
Note
Refer to the operation manual of the
Log Data Collection Set for details.
WARNING
Ensure there are no explosive gas atmospheres present before connecting
anything to the USB port of the gas detector. For USB port, note that
Um=5.5V
Flashes