Modello - Modèle - Model EULNSxx
Modell - Modelo - Modelo EULLSxx
STAGE
STATE REVISION
ORD.
A
DATE
05.05.2020
Fabbricante - Constructeur - Manufacturer
Hersteller - Fabricante - Fabricante
Epta Spa - Unità locale:
Via degli Alpini 14 - 32020 Limana
(BL) ITALIA Tel. 0437/9681 Telefax 0437/967434
PAGE:
39/58
N° DOC.
UM000440
Make sure that power supply voltage corresponds to the values appearing on the rating
plate of the refrigerator.
Consider also that the maximum allowable power voltage variation is
+/-6%.
IMPORTANT: THE REFRIGERATOR MUST BE PROPERLY EARTHED. The manufacturer disclaims all
responsibility for damage resulting from non-observance of this safety principle. If the refrigerator
must be installed far from the power point, make certain that the connection complies with the
standards in force.
THE MANUFACTURER DISCLAIMS ALL RESPONSIBILITY FOR ANY PERSONAL INJURY OR PROPERTY
DAMAGE ARISING FROM INCORRECT INSTALLATION.
6. TECHNICAL SPECIFICATIONS
The built-in electrical installation is composed of control and safety devices adequately lodged in
the cabinet. The relevant wiring diagrams and part lists are contained in a sealed plastic envelope
together with the present booklet. Keep such documents with the booklet.
The technical data,
which are also reported on the rating plate inside the showcase (see fig. 13 on page 22),
are shown in table III, page 22.
THE SOUND LEVEL GENERATED BY THE RUNNING REFRIGERATOR IS BELOW
70 DB(A). THE REFRIGERATOR GENERATES NO HARMFUL VIBRATIONS.
Thermostat adjustment is reserved for the technical after-sales service only.
7. LOADING PRODUCTS
Switch the cabinet on by the wall cutoff switch. As soon as the cabinet is on it will start its cooling
cycle. Allow about two hours before loading any products, which must already be at their preserva-
tion temperature. THE CABINET IS FACTORY-REGULATED FOR THE ANTICIPATED PERFORMANCE.
When loading products make certain that:
• they are similar in size and type;
•
the load limit line is not exceeded and products do not hamper correct cool air circula-
tion (see fig. 18, page 24).
ATTENTION: maximum load capacity for the deck pan is 250 kg/m
2
and for the shelves
is 80 kg/m
2
.
8. USE
STAGE showcases were designed and manufactured exclusively for the display of prepacked fresh
food like sausages, dairy produce, delicatessen, pre-packed food and meat, dried pastry and pre-
cooked food a (class 3M2, 3M1, 3M0).
Their purpose is to keep food temperature, not to bring it down. Therefore, when introduced, THE
FOODSTUFFS MUST ALREADY BE AT THEIR CONSERVATION TEMPERATURE. Do not load foods that
have undergone heating.
For best cabinet operation we recommend:
• loading the products as explained in the preceding section;
• Never leave upper glass sliders open or ajar. It is advisable to often check that all sliders are clo-
sed: you will thus avoid unnecessary energy consumption and frost build-ups on the walls and you
will also allow better foods preservation.
Summary of Contents for STAGE EULLS Series