PREPARATION
Place the heater on a fi
「m, Level surface and plug into a grounded 120 V, 60 Hz powe「 outlet and turn on
the powe「switch on the rear of the unit. Only operate heate「in upright positio「,.
Insert two AAA batteries into the remote control befo陀using [batte「ies not included).叫Not all products
will include a remote control.)
Please note that infrared heaters do not heat Like a t「aditional space heater. You should not expect infra「ed
heate「s to blow hot air like a traditional space heater. Infrared heate「E heat objects not air. Infrared heaters
are intended to supplement an alr写ady heated, insulated room. Square footage specifications assume a
single enclosed room not an entire home. Infrared heaters do not heat through walls, floo「s, and a陀
「,ot intended to replace a main heat source. Infrared heat can take at Least 24 h口U陌to wa「m a room but
operate much more efficiently to maintain the desired temperature. Infrared heaters will not work well in
uninsulated unheated spaces Like sc「eened in porches, RV's, garages, unheated basements, etc.
TROUBLESHOOTING
PROBLEM
The heate
「 does not
tu
「n on.
The heate
「 displays
an erro『code
“
E1
”
The heate
「 displays
an error code '"E2
”
POSSIBLE CAUSE
1. The powe
「 C口时is not plu回国in.
2. The elect「icity at the main fuse
box is
『1口t WO「king.
3. The battery in the remote
control is dead.
4. The the
「m口stat on the heater
is set lowe
「 than the room
temperature.
5. The powe
「 switch in the back
of the unit is not in the ON
position.
1. The heater has ove「heated.
2. Insufficient power t口 the unit
3. The air filte「 is clogged.
4. Insufficient ai
「 flow to the
heater.
1. Tempe
「亩tur哩senso「 not
functioning prope
「Ly.
CORRECTIVE A!町ION
1. Plug the powe
「 cor甘into an
elect
『·ical outlet.
2. Check the elect「icity at the main
fuse box.
3. Replace the batte
「ies in the 『飞�mote
control.
4. Inc
「-ease the thermostat
temperature on the heater fo
「 a
highe
「 heat setting.
5. Switch the powe
「 switch to the ON
position.
1. Unplug the heater from the wall,
wait a few seconds then plug the
powe
「 C口rd back in.
2. Make su
同
the unit is plugged into
a dedicated 3-prong outlet, with no
extension cords o
「 SU咱B protectors.
3. Clean the ai
「 filter located 口n the
back of the unit. see page 13.
4. Move the unit at least 3ft from the
wall.
1 . Please contact technical support.
CONTROL PANEL
份
n2]::
High Low Eco
C二C二ζ二C二C二
非
--..
(!)
--
(5)
PART
NAME
DESCRIPTION
High,
Low,
ECO
Heat
Indicates when the heate
「 is in High, Low, o「 ECO heat mode
Indicator Lights
2
Digital Display
Readout of the set room temperature o
「 timer value
3
Fan lndicat口r Light
Indicates when the fan is on
4
USB Charging Po
「t
Cha咱es any compatible USB device. Output Rating: 2.1A
5
Fahre
『1heit
/
Celsius Indicates that the tempe
「百tu
同
is being displayed in Fah
『凹heit
Indicator Light
or Celsius
6
Timer Indicator Light
Indicates when the timer function is active
7
Power Indicator Light
Indicates when the unit is receiving powe
「 from the wall outlet
B
Time
「 Button
Powe陌口ff unit afte
「 a selected time
9
Temp-Down Button
Dec
「eases the set temperatu陀
10
Powe
「 Switch Button
Powe
『-s the heate「 ON口r OFF
, 1
Temp-Up Button
Increases the set temperatu陀
12
He ate
「 Mode Button
Cycles between High
I
Low
I
ECO Heat Modes
Summary of Contents for EP23757
Page 1: ...HEATER INFRARED QUARTZ EP23757 ...
Page 5: ...Factory No HT1167 ...