Observe Flame Height When Lit: The burner will display blue and yellow
flames. These flames should be a blue / yellow color between 15~20 in.
height (See Figure 16). These flames should not be yellow or produce thick
smoke. This would indicate an obstruction of airflow through the burners. The
flames should be blue with straight yellow tops.
Figure 16
Yellow
Yellow
Light Blue
Light Blue
Blue
Blue
Good
Bad
WARNING:
For your safety, read and follow the Lighting Instructions in this
manual and in the Rating Plate on the appliance. IMPROPER LIGHTING
PROCEDURES COULD RESULT IN A FIRE HAZARD OR EXPLOSION HAZARD
OR PROPERTY DAMAGE, INJURY OR LOSS OF LIFE.
TO TURN OFF GAS
1. Push in gas control knob slightly and turn to “OFF”.
Figure 15
gas control knob
ignition button
OFF (APG.)
MAX
(MÁX.)
1 AAA
1.5V
IGNITOR
( Encendedor )
ON/MIN
(ENC./MÍN.)
LIGHTING INSTRUCTIONS
1. Push in gas control knob slightly and
2. Turn gas control knob to “ON/MIN”.
3. Push in gas control knob all the way
4. If the burner does not light in 15
1. Push in gas control knob slightly and turn to “OFF”.
TO TURN OFF GAS
INSTRUCCIONES DE ENCENDIDO
PARA CERRAR EL GAS
1. Presione ligeramente la perilla de control del gas y gírela a la
2. Gire la perilla de control del gas a “ENC/MÍN” (encendido/mínimo).
3. Presione la perilla de control del gas hasta el fondo y mantenga presionada.
4. Si el quemador no se enciende en 15 segundos, suelte la perilla y esta
encender el quemador nuevamente, repita los pasos 1 al 3.
1. Presione ligeramente la perilla de control del gas y gírela a la
turn to “OFF”.
and hold. Continue to press the
ignition button for 15 seconds.
seconds, release the knob and it will
pop back out. Wait 5 minutes before attempting
to light the burner again, repeat step 1 to 3.
posición “APG” (apagado).
Siga presionando el botón de encendido durante 15 segundos.
volverá a su posición hacia afuera. Espere 5 minutos antes de intentar
posición “APG” (apagado)
OPERATION INSTRUCTIONS
OPERATION INSTRUCTIONS
20