If the values lie outside of these limits, they can be adjusted on the indoor unit.
See the
Calibration
section.
Place the sensor close to the indoor unit, and
leave it lying there for approx. 30 minutes
so that the temperature stabilises. Read
the values for the temperature and humidity,
and compare these. The temperature values
should be within 1 °C (accuracy ±0.5 °C)
and the humidity values should be within 6 %
(accuracy ±3 %).
If you have any additional thermometers/
hygrometers connected, press [ C ]
(2) repeatedly to switch between these.