. 20140210

Battery status: 
Bad, Full, 
Discharge or 
Charge

Capacity indicator for 
9 V batteries (2 x)

USB-status

Capacity indicator for R03, R6, R14 
and R20 batteries (4 x)

Battery Charger

Art.no. 18-5105 

Model V-9688-UK

 

36-5105  

V-9688

Please read the entire instruction manual before use and save it for future reference. We reserve the right for any errors in text or images and for making any necessary 
technical changes to this document. If you should have any questions concerning technical problems please contact our Customer Services. 

5. Discharging

Discharging removes the memory effect from the batteries which are 
not fully discharged and result in a diminished charging capacity. 
1.  Connect the adaptor to a power point and the DC plug to the charger.
2.  Insert 1 to 4 batteries (R03, R6, R14 or R20) according to the polarity 

markings on the charger. Press them securely against the bottom.  
(9 V batteries (6F22) cannot be discharged).

3.  Press the discharge button on left side of the display.
4.  “DISCHARGE” is shown and the blue background light is 

illuminated as long as discharging is in progress.

5.  The battery icons flash as long as discharging is in 

progress for any of the batteries.

6.  Charging starts automatically when the batteries are discharged.

6.  USB connection

1.  The USB connection can only be used when the batteries 

in charger are fully charged or if the charge is empty.

2.  The USB symbol will be lit when the charger’s USB 

connection is ready to use.

3.  Connect the USB device to be charged to the USB 

outlet on the back of the charger. 

N.B

. Power consumption cannot exceed 500 mA (5 V).

7. Disposal

Sort and recycle products where possible, instead of disposing 
of them. All electronic products, batteries and packaging material 
etc. should be sorted and processed according to local 
environmental regulations.

8. Specifications

Operating voltage 

Input Power 

100–240 V AC, 50/60 Hz 

Output Power 

12 V DC, 1000 mA (centre positive)

Using the AC/DC adaptor: DC 12 V 1000 mA

Charging Current

Ni-MH capacity

Charging time

R03 500 mA

R03 1000 mAh

2 hours

R6 1300 mA

R6 2500 mAh

2 hours

R14 1300 mA

R14 2800 mAh

2.25 hours

R14 4500 mAh

4 hours

R20 1300 mA

R20 2800 mAh

2.25 hours

R20 9000 mAh

9 hours

Discharge current: 

400 mA for R03, R6, R14 and R20

Detection method:

-ΔV auto cut-off for R03, R6, R14, and  
R20 batteries

Charging current 9 V
Charge time 9 V

30 mA
10 hours (timer controlled)

Compatible batteries

R03 500–1100 mAh
R6 1300–2700 mAh
R14 1300–4500 mAh
R20 1300–10000 mAh
9 V (6F22) 100–250 mAh

N.B.

 The charging time can vary depending on the capacity and condition 

of the battery.

Discharge button               LCD display                       Backlight

1. Safety

• 

Only charge rechargeable NiMH/Ni-CD batteries;

 

sizes R03, R6, R14, R20 or 6F22 (9 V).

• 

NEVER try to recharge regular dry-cell batteries, alkaline batteries or 

 

non-rechargeable batteries in the battery charger.

• 

Never use a higher charging current than that which is

 

recommended or that is marked on the battery.

• 

Always charge rechargeable batteries before using them for the

 

first time and top them up again every second month.

• 

Observe the battery polarity markings on the charger.

• 

Do not expose the charger to water or sources of excess heat.

• 

Do not use the charger if the connection cable or

 

power adaptor is damaged.

• 

The charger is only intended for indoor use.

• 

The batteries will become warm when charged, be careful

 

when removing them.

• 

Only use the enclosed adaptor to power the charger.

• 

Unplug the adaptor from the power point when the charger is not in use.

2. Functions

• 

Used for quick charging Ni-MH batteries. 

• 

Charges e.g. R20 1200 mAh in two hours and 15 min.

 

and 9000 mAh in 9 hours.

• 

Compatible battery sizes: R03, R6, R14, R20 and 6F22 (9 V)

 

(6F22 (9 V) Timer-charged only).

• 

Microprocessor controlled charging. 

• 

Negative delta-V cut off function (-∆V).

• 

Timer protects against overcharging.

• 

Protected against short circuiting.

• 

Reverse-polarity protected.

• 

Bad battery indicator.

• 

Outlet for charging devices with a USB connection (5 V, 500 mA).

• 

Do not let children use the charger without supervision. It is not a toy.

3. Contents

• 

Charger V-9688

• 

230 V adaptor

• 

Instruction manual

4. Charging

1.  Connect the adaptor to a power point and the DC plug to the charger.
2.  Insert 1 to 4 batteries (R03, R6, R14 or R20) according to the polarity 

markings on the charger. Press them securely against the bottom.  
9 V batteries (6F22) can be charged one or two at a time.

3.  The charger determines the correct charge automatically.  

The display’s icons graphically demonstrate the charging process. 

4.  “CHARGE” is displayed when any battery is being charged.  

The display will also illuminate as long as charging is in progress.

5.  When all batteries are charged “FULL” will be displayed.
6.  Disconnect the adaptor from the socket and remove the batteries when 

charging is finished.

Incorrect batteries

Battery status: When charging commences the charger makes sure that all 
the batteries are capable of being recharged and that none of them is inserted 
incorrectly. If any of the batteries cannot be charged or are misaligned, “BAD” 
will be shown and the icon for the corresponding battery will flash. Charging is 
interrupted until the fault has been corrected (i.e. the defective battery has been 
removed or realigned).