background image

NOTE:
The value of the voltage set for the “UV Alarm” should be
equal to or higher than the value set for “UVP” or else the
unit will shut-down without any audible warning.

˙

O/P Parameter 

Model

110V
230V

97 VAC ~ 123 VAC

194 VAC ~ 246 VAC

Setting value range

Model

110V
230V

47 Hz ~ 63 Hz
47 Hz ~ 63 Hz

Setting value range

Model

12V
24V
48V

10.5 VDC ~ 11.5 VDC

21 VDC ~ 23 VDC
42 VDC ~ 46 VDC

Setting value range

5. UV Alarm : Setting Under Voltage (UV) alarm. When the input
    voltage is lower than the set value, the SD-series will sound a
    “beep” to remind you that the unit is going to shut-down. In the
    meantime, the contact in the internal Dry Contact Relay will
    open / close.
    Default= 10.5 VDC @ 12 V Model, 21 VDC @ 24 V Model.
                              42 VDC @ 48 V Model

1. O/P Voltage : Setting the SD-series output voltage on the
    inverter operation.  
    Default= 110 VAC @110 V Model, 230 VAC @ 230 V Model

2. O/P Frequency : Setting the SD-series output frequency on the
    inverter operation.
    Default= 60 Hz @ 110 V Model, 50 Hz @ 230 V Model.

3. Sync Frequency : If a generator is distorted. The output
    waveform (too low frequency) is used as AC source, the allowed
    frequency window for the incoming AC power can be enlarged.

9

Summary of Contents for CR-10

Page 1: ...CR 10 Remote Control User s Manual www cotek com tw ...

Page 2: ...g messages are displayed on the LCD panel screen LED Indications GRID Displays incoming AC input status 80 46 2 φ3 3 92 92 30 5 5 5 71 71 AC Input DC AC Inverter LED Status AC input ON Inverter AC Working Inverter AC Saving Inverter AC shunt down Green Green Blink OFF AC input OFF Green OFF LED Status Inverter Displays the SD series working statuses Alarm LED Status Abnormal Normal Red OFF Alarm D...

Page 3: ...n You can use the Page Down button to scroll through the menus Enter Confirms a selection or value ON OFF The SD series can be activated by the button Press ON OFF button the SD series to startup If you want to turn OFF the SD series press the ON OFF button longer than 3 seconds Enter Setup Menu Press the button longer than 3 seconds The SD series will change to Select Menu which appears on the LC...

Page 4: ...controller Green Terminal reference 2 PIN Function 1 ALM 2 3 CTL ENB 4 VCC J1 Jump CTL Input Voltage 5 60 VDC 0 V Open Turn ON Turn OFF SD series J1 Jump CTL Input Voltage 5 60 VDC 0 V Short Turn OFF Turn OFF SD series J1 jump short J1 jump open Note The J1 jump default mode is short 3 ...

Page 5: ...LM Battery is common ground RJ 45 port connect to inverter reference 3 ALM PIN1 When the SD series has the warning or the protection displayed simultaneously this ALM pin will changing output to 5 Volt 10mA control signal to provide the user ENB PIN3 User can USE this ENB pin to control the SD series to turn ON or turn OFF Vcc PIN4 This is LCD remote control panel ground 4 ...

Page 6: ...quency Function 8 Overload Alarm Function 9 Saving Level Function 11 Saving Interval Function 12 Bypass Relay Function 13 OVP Setting Function 0 OVP Recovery Function 1 UVP Setting Function 2 UVP Recovery Function 3 UV Alarm Function 4 I P Parameter O P Parameter RST to Default Press button longer than 3 seconds The SD series enters the select Menus consisting of four layers 1 User Interface 2 I P...

Page 7: ...LCD Contrast 0 100 SETT value 1 LCD contrast Sets the LCD screen contrast Default 50 Setting range 0 100 Setting Menu LCD Auto off 0 120 SETT value 2 LCD Auto off Sets the LCD screen backlight auto off timer Default 120 seconds Setting range 0 120 seconds 4 Buzzer setting Set the LCD remote control for the buzzer sound Default MSG Alert SHDN Setting range 0 7 Setting Menu RS 232 Baud rate 0 1 2 3 ...

Page 8: ...etting English Italian Spanish French German 6 Shut down retry When SD series is shut down under OVP UVP Overload or short circuit conditions the inverter will automatically try to restart according to the setting value Default 5 Setting range 0 15 Setting Menu Buzzer Setting 0 1 2 3 4 5 6 7 Disable SHDN Alert Alert SHDN MSG MSG SHDN MSG Alert MSG Alert SHDN SETT RS 232 Buzzer Beep sound Setting M...

Page 9: ...VDC 20 VDC 22 VDC 40 VDC 44 VDC Setting value range Model 12V 24V 48V 11 5 VDC 13 5 VDC 23 VDC 27 VDC 46 VDC 54 VDC Setting value range 3 UVP Setting Setting Under Voltage Protection UVP and Shut down on the inverter operation Default 10 VDC 12V Model 20 VDC 24V Model 40VDC 48V Model 4 UVP Recovery When the DC input voltage is below the set UVP value the SD series shuts down Once the input voltage...

Page 10: ...han the set value the SD series will sound a beep to remind you that the unit is going to shut down In the meantime the contact in the internal Dry Contact Relay will open close Default 10 5 VDC 12 V Model 21 VDC 24 V Model 42 VDC 48 V Model 1 O P Voltage Setting the SD series output voltage on the inverter operation Default 110 VAC 110 V Model 230 VAC 230 V Model 2 O P Frequency Setting the SD se...

Page 11: ...series inverter enters power saving mode it will detect AC Load periodically Default 2 0 Seconds Setting range 1 0S 2 0S If the AC Load is 3 times higher than Saving Level inverter will recover and output normally to AC Load 0 1 2 3 4 5 6 7 Example1 AC input 230 VAC 50Hz User setting Value 7Hz When the SD series Output frequency is within The Range of 43 Hz 57 Hz the internal transfer relay will c...

Page 12: ...d frequency is beyond the range set under Sync Frequency window The transfer relay will switch ON or OFF based on conformance to the Phase and Sync Frequency Always supplied by battery until which has run down UVP then switch to grid Normal Exacting On line 1 2 3 The transfer relay will switch ON or OFF Conformance to phase and frequency synchronization will not be considered Model SETT value Haph...

Reviews: