Ground Fault Circuit Interrupters (GFCI)

Installations in Recreational Vehicles (for North American approvals) will
require GFCI protection of all branch circuit connected to the AC output of
the hardwire terminal equipped Inverter.In addition, electrical codes
require GFCI protection of certain receptacles in residential installations.
While the pure sine wave output of the Inverter is equivalent to the
waveform provided by utilities, compliance with UL standards requires us to 
test and recommend specific GFCI.
Cotek has tested the following GFCI – protected 20A receptacles and found
that they functioned properly when connected to the output of the Inverter.

3-7. Inverter Operation

To operate the power inverter, turn the main switch ON.  The power inverter 
is now ready to deliver AC power to your loads.  If there is several loads use,
turn them on separately after the inverter has been “ON” in order to prevent 
the OVP present caused by the surge power.

3-7-1.

 Set the power switch to the “ON” position and the buzzer will send

           out “Beep” sounds at the moment the inverter will do self-diagnosis, 
           then the Power Status LED  indicators will also appear various colors.  
           Finally the buzzer will sound another “Beep” and the Power Status 
          LED indicators will turn to “Green” color, the inverter starts working 
          successfully.

3-7-2.

 Set the power switch to the OFF position, the inverter stops and all

            the lights that are On, go Off.

3-7-3.

 Set power inverter switch to the ON position and turn the test load 

           On.  The inverter should supply power to the load.  If you plan to 
           accurately measure the true output r.m.s. voltage of inverter, a meter
           such as FLUKE 45 BECKMAN 4410 or TRIPLETT 4200 must be 
           used.

-15-

Summary of Contents for SE350 series

Page 1: ...SE350 Series Pure Sine Wave Inverter User s Manual WWW COTEK COM TW...

Page 2: ...1 Front Panel Operation 3 2 Rear Panel Operation 3 3 Protections Features 3 4 Installation 3 5 Making DC Wiring Connections 3 6 AC Safety Grounding 3 7 Inverter Operation 4 Troubleshooting guide 5 Mai...

Page 3: ...eries or Flammable materials or in locations which require ignition protected equipment This includes any space containing gasoline powered machinery fuel tanks or joints fittings or other connection...

Page 4: ...isolated design High efficiency Capable of driving inductive capacitive loads at the start moment A LED Indicator with twin color displays all operation status Loading and temperature controlled cool...

Page 5: ...ature 20V 0 5V 21V 0 5V 24V 0 5V 30V 0 5V 31V 0 5V 29V 0 5V 40V 1V 42V 1V 48V 1V 60V 1V 62V 1V 58V 1V 10V 0 25V 10 5V 0 25V 12V 0 25V 15V 0 25V 15 5V 0 25V 14 5V 0 25V 20V 0 5V 21V 0 5V 24V 0 5V 30V 0...

Page 6: ...2 2 M SE350 de rating curve echanical Drawing of Socket 6 150 5 91 68 2 68 35 7 1 41 116 0 4 57 22 0 87 127 5 00 187 7 36 0 20 30 40 35 45 55 50 60 25 200 250 300 350 400...

Page 7: ...ced line of mobile AC power systems available To get the most out of the power inverter it must be installed and used properly Please read the instructions in this manual before installation and opera...

Page 8: ...t Voltage Selected by Dip Switch Power Saving Dip Switch ON OFF 1 0 Frequency 50Hz 60Hz Output Voltage S1 S2 Dip Switch 0 1 0 0 0 1 0 1 1 1 C A V 0 0 2 C A V 0 0 1 8 C A V 0 2 2 C A V 0 1 1 C A V 0 3...

Page 9: ...D shows green orange red green Normal LED green light Saving mode LED Flashing green light once every two seconds shut down after 30 minutes O P over load 100 115 LED red light two short beep shut dow...

Page 10: ...nit make sure the main switch must be REMOTE 3 2 3 Ensure the remote control contact is off 3 2 4 Remote Port Place 0 75mm2 and Screw type cable between the remote port and the panel 3 2 5 Remote port...

Page 11: ...48V battery or the other power sources is positive is negative Reverse polarity connection will blow internal fuse and may damage inverter permanently Model Minimum Maximum 62 0 15 5 10 0 40 0 20 0 31...

Page 12: ...ing requirements 3 4 1 Dry Do not allow water to drip or splash on the inverter 3 4 2 Cool Ambient air temperature should be between 20 and 40 the cooler the better 3 4 3 Safe Do not install in a batt...

Page 13: ...ut terminals of the Inverter Your cables should be as short as possible Ideally less than 6 feet 1 8 meters enough to handle the required current in accordance with the electrical codes or regulations...

Page 14: ...the neutral conductor from the utility is tied to ground at the AC breaker panel For models configured with a transfer relay while AC utility power is presenting and the Inverter is in bypass mode thi...

Page 15: ...he power inverter is now ready to deliver AC power to your loads If there is several loads use turn them on separately after the inverter has been ON in order to prevent the OVP present caused by the...

Page 16: ...nates the red LED a Blinking fast Over input voltage OVP Check input voltage Reduce input voltage b Blinking slow Low input voltage UVP Recharge battery Check connections and cable c Blinking Intermit...

Page 17: ...anty will be considered void if the unit has suffered any obvious physical damage or alteration either internally or externally and does not cover damage arising from improper use such as plugging The...

Page 18: ...No 33 Sec 2 Renhe Rd Daxi Dist Taoyuan City 33548 Taiwan Phone 886 3 3891999 FAX 886 3 3802333 2015 12 A3 E mail sales cotek com tw http www cotek com tw...

Reviews: