TOTAL COUNTER
The micro-controller automatically counts any paper being run through the transport.
This count is displayed as the EZ CREASER is operating and when it is stopped. To clear
the counter:
DISPLAY READS
Clr Tot Cnt = Y/N
Total Count = 0
SETTING THE DOUBLE SHEET DETECTOR
Note: Sheet detector works on the basis of measurement comparison using the length
of the sheet to verify more than one sheet.
To turn on:
1.
=Display will read (measuring length)
Machine will automatically start to advance
2. Place sheet of job to be run in machine
3. After paper runs through the machine will stop and a dashed line will appear in the
bottom of left corner of display, thus indicating that the sheet detector is activated.
To turn off:
1.
=Dashed line on display will vanish from
display, thus indicating that the sheet
detector is off.
PROGRAMMING NOTES
•
The micro controller is capable of positioning creases from 1/2 of an inch from
the lead edge to ½ inch from the tail edge and up to 26 inches from the lead
edge.
•
The crease bar can be programmed to strike single or multiple locations with a
capacity of 10 locations.
•
When programming multiple locations to crease, the distances must be entered
in an ascending order. For example, if 1.5 is the first location, the controller will
not accept an entry of 1.2 after this. If this is attempted, the display will read
“crease out of range”
•
If the incorrect key is pushed while programming, a beep will occur and the
display will flash “keyboard sequence error”. Wait 3 seconds then respond as
prompted.