Next, remove the non-operator side cover. Loosen the belt tensioner idler pulley
bracket. You do not need to remove these as loosening them will allow enough
movement to free the belt. Remove the belt. Walk the motor belt off the inner pulley. If
it is too difficult to walk off you could loosen the motor and pull it up as it is mounted in
slots.
Reach in under the exit side of the machine with your right hand and slide the shaft out
of the left side enough to slide the assemblies on and off the shaft.
reverse procedure to install components back on.