Version
4.0
48
APPENDIX C: TECHNICAL SPECIFICATIONS
Fuel Type:
#2 Yellow Shelled Corn Fuel (CLEANED)
Hardwood Pellet Fuel
Moisture Content: 14% or less
(10- 12% preferred)
A.P.F.I. residential fuel
Heat
Content:
10,000
Btu/lb*
Heat
Content:
8200
BTU/lb
Ash
Content:
3%
maximum Ash
Content:
1%
max
Bulk Density: 40 lb./cubic ft. min
Moisture Content: 8% max
Size:
1/4”
to
3/8”
diameter
1.5” long max
Fines: 1% max through 1/8
th
screen
Hopper Size:
72 pounds corn or 55 pounds wood pellets
Flue Size:
4” recommended. If less than 10 feet use of 3 inch pipe is approved.
Flue Type:
PL double wall vent with stainless steel inner liner
Air Inlet:
3 inch by .15 inch walled steel pipe
Auger Type:
1
1/8”
cup Auger Feed System
Controls:
Country
Flame
Intelli-Choice
Control Board
Electrical:
120 Volts, 2.4 Amp, 60 Hz
Measurements:
CROSSFIRE HEIGHT (at front)
22.5”
CROSSFIRE
DEPTH
(from
shroud) 14.0”
CROSSFIRE
WIDTH
(rear)
26.0”
CROSSFIRE
WIDTH
(at
shroud
mount)
25.5”
Weight :
STOVE
WEIGHT 220
POUNDS
Clearances:
UNIT
TO
SIDEWALL
7”
UNIT TO SIDE TRIM
7”
UNIT TOP TO SIDE TRIM
9.25”
UNIT TOP TO MANTLE
9.25”
HEARTH
FLOOR
TO
MANTLE
32”
NONCOMBUSTIBLE FLOOR PROTECTION (front)
6”
NONCOMBUSTIBLE FLOOR PROTECTION (sides)
6”
Shroud Measurements:
SHROUD WIDTH (standard)
42.0”
SHROUD HEIGHT (standard)
30.0”
SHROUD WIDTH (oversized)
48.0”
SHROUD HEIGHT (oversized)
32.5“
*BTU/lb can vary depending on the moisture content of the corn.