SAFETY RULES
Warning:
An outside air kit must be installed
on the Inglenook Fireplace.
Inglenook
air
openings are never to be obstructed. Any obstruction of combustion air openings can
create danger both for the dwelling and the occupants.
Warning:
The fireplace must be operated with the doors fully opened or fully closed. If the unit
is operated with the doors fully opened, the optional fire screen
MUST
be used.
Warning:
When cleaning, all ashes should be placed in an approved metal container with a tight
fitting lid. The closed ash container should be placed on a non-combustible floor or on
the ground outside the house, pending final ash disposal. The ash should be retained in
a closed container until all ash and cinders have thoroughly cooled.
Warning: Keep combustible materials at least 48 inches from the front of the fireplace.
Never use gasoline, kerosene, charcoal lighter fluid or similar liquids to start or
rekindle a fire in this fireplace. Keep all such liquids well away from the fireplace at
all times.
Warning:
Do not use
grates, andirons, or other methods of supporting fuel off the floor of the
firebox. Using such devices can cause “over burn” and generate excessive
temperatures.
Warning: Never
leave children unattended when there is a fire burning in the fireplace.
Warning:
Do not use a fireplace insert or other products not specifically approved for use with
this fireplace. Contact your local authorized Country Flame Dealer or Country Flame
directly for any necessary clarification.
Warning:
Country Flame
does not recommend
the use of solid fuel fire log products. If used, do
not poke or stir the logs. Follow all solid fuel fire log instructions, warnings, and
caution markings on the packaging prior to use.
Warning:
The use of some fuels (e.g. charcoal) can generate carbon monoxide and create hazards
associated from carbon monoxides. Ensure the hazards of any fuel being used in the
Inglenook are understood before burning occurs.
Warning:
Country Flame
strongly recommend
s the use of smoke and carbon monoxide
detectors. At a minimum, these devices should be checked on a semi-annual basis.
Warning:
All Inglenook fuel loads must be behind the log retainer, i.e., no fuel should be
allowed between the log retainer and glass doors.
Warning:
Consult with your local authorized Country Flame Dealer, the local city code
department or the local fire department concerning installation of this product.
Summary of Contents for Inglenook IWZC-02
Page 8: ...8 WARNOCK HERSEY SAFETY LABEL Version 7 0 ...
Page 35: ...FIGURE 24 EXAMPLE MULTIPLE CHIMNEY INSTALLATION INTERIOR SPACE Version 7 0 35 ...
Page 36: ...Class A AC CHIMNEY INSTALLATION AIR COOLED CHIMNEY Version 7 0 36 FIGURE 25 AC CHIMNEY ...
Page 37: ...FIGURE 26 EXAMPLE CHIMNEY INSTALLATION exterior space Version 7 0 37 ...
Page 47: ...________________________________________________________________________ Version 7 0 47 ...
Page 50: ...________________________________________________________________________ Version 7 0 50 ...