17
ASSEMBLY & OPERATION INSTRUCTIONS MANUAL - 30 GALLON TRAILER SPRAYER #1046832
TROUBLESHOOTING
PUMP WILL NOT START
Check
:
• Correct voltage (±10%) and electrical connections
• Fuse or breaker
• Pressure switch operation and correct voltage
at switch
• Rectifier or motor for open or grounded circuit
• Locked drive assembly
PUMP WILL NOT PRIME
(No discharge with motor running)
Check:
• Debris in strainer
• Restriction (kinks) in inlet/outlet tubes
• Debris or swelling in inlet/outlet valves
PUMP WILL NOT SHUT OFF
(Output line closed and no leaks)
Check:
• Air trapped in outlet line or pump head
• Correct voltage to pump
• Debris in pump inlet/outlet valves
• Loose drive assembly or pump head screws
• Pressure switch operations/adjustments
LEAKS FROM PUMP HEAD OR SWITCH
Check:
• Loose screws at switch or pump head
• Switch diaphragm ruptured or pinched
• Punctured diaphragm if fluid is present
PROBLEM / CAUSES AND REMEDIES: