28
ver.071217-2.10
iLEARN
System Manual
iLEARN Door Control Menu Screens
(continued)
04 - Max volts – ‘1’ indicates that the maximum rate of change algorithm is being utilized in-
stead of the settable ROC parameter. This is in place for emergency acceleration/decelera-
tion needs and is not presently used. Should be ‘0’ in normal operation.
05 - Max ROC – ‘1’ indicates that the maximum rate of change algorithm is being utilized in-
stead of the settable ROC parameter. This is in place for emergency acceleration/decelera-
tion needs and is not presently used. Should be ‘0’ in normal operation.
06 - Direction command. ‘1’ = close, ‘0’ = open.
07 - Run – Run command - ‘1’ indicates motor controller is being commanded to run. ‘0’
means stop.
08 - Control place – Factory use. Should be ‘0’ in normal operation.
1.4.10 Motor Status Bits
06 - ‘1’ = close, ‘0’ = open.
07 - Run ‘1’ indicates inverter is generating an output, and motor should be running.
1.4.11 Motor Fault Bits
03 - ‘1’ = heat sink temperature sensor measured over 100 degrees Celsious. Should be ‘0’
in normal operation.
04 - ‘1’ = motor control parameters are out of range when the motor was commanded to run.
Should be ‘0’ in normal operation.
05 - ‘1’ = overcurrent condition (>12.5A) has been detected by the control software. Should
be ‘0’ in normal operation.
06 - ‘1’ = DC bus voltage fell below 75V while the motor was commended to run. Should be
‘0’ in normal operation.
07 - ‘1’ = DC bus voltage has exceeded 450V. Should be ‘0’ in normal operation.
08 - ‘1’ = overcurrent (>15A) condition has been detected by the inverter circuit. Should be
‘0’ in normal operation.
1.4.45 Firmware Version -
This is the actual version of firmware loaded in the iDrives.
Summary of Contents for iDRIVE
Page 8: ...8 ver 071217 2 10 iLEARN System Manual PA PAE INTERLOCK PO 70 3A...
Page 14: ...14 ver 071217 2 10 iLEARN System Manual iLEARN Door Control...
Page 19: ...19 ver 071217 2 10 iLEARN System Manual...
Page 20: ...20 ver 071217 2 10 iLEARN System Manual...
Page 36: ...36 ver 071217 2 10 iLEARN System Manual iDRIVE VFD Floor Control...
Page 38: ...38 ver 071217 2 10 iLEARN System Manual iDRIVE G Car Top Control...
Page 41: ...41 ver 071217 2 10 iLEARN System Manual...
Page 63: ...63 ver 071217 2 10 iLEARN System Manual Doors Closing Doors Opening...