2.5 Warning Bell Timer -
Default = 5.0s. Time the Warning Bell sounds before the gate begins
closing. Not in effect while in Fireman’s Service.
2.6 Timed Close -
Default = 1.0 min. Time before an Automatic Close operation is initiated follow-
ing an Open operation. The Automatic Timed Close function is enabled by setting the ATC input
high.
2.7 Constant Pressure Close -
(On or Off) Default = ON. When ON, the close button must be
held until the doors and gates are completely closed. When OFF, the close button requires Mo-
mentary Pressure.
2.8 Stay Set -
(On or Off) Default = ON. When ON, an Automatic Open will be generated when
the doors “bounce” by ¾” or more. Both the Open and Close Door iSENSORs must be initialized
for Stay Set to operate.
2.9 Operate Together -
(On or Off) Default = OFF. When ON, Passenger Sequence Operation is
turned off and the doors and gate operate together.
2.10 Fire Service Type
- Standard ASME (default) or New York City or Chicago
Door Parameters
This menu allows hoistway door operational parameters to be adjusted to
suit the needs of individual installations.
IMPORTANT - For changes to these Parameters to take effect, the
COURION CANbus Network must by RESTARTED using Restart
System under Diagnostics.
3.1 Extra Door Time -
(On or OFF) Turning this ON changes the Door Timeout from 30s to 50s.
This is used when you have a large single section door panel. Call Courion for additional details.
This parameter does not affect the Gate Timeout (30s).
3.2 Fast Door Speed -
Default = 100%. (100% corresponds to 60Hz). This is the speed the
doors run before reaching the “Slowdown Distance” (approximately 8” from FULL OPEN or FULL
CLOSE).
3.3 Slow Door Speed
- Default = 50%. (50% corresponds to 30Hz). This is the speed the doors
run when in the “Slowdown Distance” (approximately 8” from FULL OPEN or FULL CLOSE).
Summary of Contents for iDRIVE
Page 8: ...8 ver 071217 2 10 iLEARN System Manual PA PAE INTERLOCK PO 70 3A...
Page 14: ...14 ver 071217 2 10 iLEARN System Manual iLEARN Door Control...
Page 19: ...19 ver 071217 2 10 iLEARN System Manual...
Page 20: ...20 ver 071217 2 10 iLEARN System Manual...
Page 36: ...36 ver 071217 2 10 iLEARN System Manual iDRIVE VFD Floor Control...
Page 38: ...38 ver 071217 2 10 iLEARN System Manual iDRIVE G Car Top Control...
Page 41: ...41 ver 071217 2 10 iLEARN System Manual...
Page 63: ...63 ver 071217 2 10 iLEARN System Manual Doors Closing Doors Opening...