43
ver.071217-2.10
iLEARN
System Manual
If your readings are substantially different than these, you may have an open/shorted connection in your CANbus Net-
work (See Step 5), or the CANH/CANL data lines reversed (See Step 6).
Step 5:
Go to the first iDRIVE on your iSYSTEM CANbus Network (and each successive iDRIVE) and take the same
readings as described in Step 4 to identify and isolate the open/shorted connection in your iSYSTEM CANbus network.
Note that all readings should be in the ranges described in Step 4 with the exception of C05 and C06 which should be
as follows:
• Red to C05 (Address In) and Black to C02 (COMMON) = +21.6VDC to +26.4VDC
• Red to C06 (Address Out) and Black to C02 (COMMON) = 0VDC
Before proceeding to the next iDRIVE on your iSYSTEM place a temporary jumper between C05 (Addriss In) and C06
(Address Out). Do not allow the jumper to short to anything metal.
Step 6
: With the CANbus terminal block removed from the iLEARN Door Control and the 120VAC power OFF, check
the CANbus Network Impedance between C03 (CANH) and C04 (CANL). The resistance reading should range from
114 ohms to 126 ohms. If not, then there is a hoistway wiring issue on C03 and C04.
THE HOISTWAY DOORS DO NOT OPERATE OR ONLY ‘CREEP’ AT ONE OR MORE OPENINGS
WHAT TO LOOK FOR
- Generally, Hoistway Doors fail to operate properly because of a problem with the iSENSORs
located in the lower door guides. iSENSOR failures can be identified as follows:
• Hoistway Doors fail to Open or Close
• Hoistway Doors operate only at “creep” speed
• Error 23 - OPEN STALL CHNG appears on the iLEARN Door Control
• Error 24 - CLOSE STALL CHNG appears on the iLEARN Door Control
Step 1
: Visually check the iSENSORs to insure they have not been damaged. Replace as required.
Step 2
: Check the alignment of the iSENSORs in the Lower Door Guides in relation to the iSENSOR Magnet on the
Lower Door Panel.
Using iLEARN Menu Items 1.3.1 to 1.3.3 Open iSENSOR, (of the iLEARN Door Control Menu Screens Section of
this Manual) manually open the hoistway doors to insure that the OPEN iSENSOR is reading the iSENSOR magnet
and that the position counter is changing in a constant and consistent manner. Adjust the iSENSOR as required.
Using iLEARN Menu Items 1.3.4 to 1.3.6 Close iSENSOR, manually close the hoistway doors to insure that the
CLOSE iSENSOR is reading the iSENSOR magnet and that the position counter is changing in a constant and con-
sistent manner. Adjust the iSENSOR as required.
Using iLEARN Menu Item 1.3.8 Door Status Bits, insure the following:
9
(Full Close) = 1 when the hoistway doors are in the FULL CLOSE position
11
(Almost Closed) = 1 when the iSENSOR magnet is over the Close iSENSOR
10
(Full Open) = 1 when the hoistway doors are in the FULL OPEN position
12
(Almost Open) = 1 when the iSENSOR magnet is over the Open iSENSOR
Summary of Contents for iDRIVE
Page 8: ...8 ver 071217 2 10 iLEARN System Manual PA PAE INTERLOCK PO 70 3A...
Page 14: ...14 ver 071217 2 10 iLEARN System Manual iLEARN Door Control...
Page 19: ...19 ver 071217 2 10 iLEARN System Manual...
Page 20: ...20 ver 071217 2 10 iLEARN System Manual...
Page 36: ...36 ver 071217 2 10 iLEARN System Manual iDRIVE VFD Floor Control...
Page 38: ...38 ver 071217 2 10 iLEARN System Manual iDRIVE G Car Top Control...
Page 41: ...41 ver 071217 2 10 iLEARN System Manual...
Page 63: ...63 ver 071217 2 10 iLEARN System Manual Doors Closing Doors Opening...