50
ver.071217-2.10
iLEARN
System Manual
Error
Code #
Error Message
14
DRIVE_ERROR__IDRIVE_VERSION -
Error 14 occurs when the iDRIVE software version reported
does not match that required by the iLearn. The installed version of the iDRIVE program can be found under
the Diagnostics - iDRIVE Monitor - Firmware Version Menu (Section 1.3.45 of the iLEARN Door Control Menu
Screens Section of this Manual). The required version of the iDRIVE program can be found under the Diagnos-
tics - Firmware Version Menu (Section 1.2 of the iLEARN Door Control Menu Screens Section of this Manual).
If you require a different version of iDRIVE software - please contact COURION at (800) 533-5760 or (314)
533-5700.
15
DRIVE_ERROR__GENERAL_FAULT -
Error 15 occurs when the iDRIVE has reported a General
Fault. Error 15 is used as a “catch all” fault for errors that are not called out in more detail by this Manual.
Below is a list of events that can trigger Error 15: (a) iDRIVE loses actuating soft motion interlock bits from the
iLEARN, or (b) iSENSOR Communication Failure
Check the condition of the iSENSOR wiring.
16
GATE_ERROR__COMMS -
Error 16 occurs when the specified Gate iDRIVE Control has stopped com-
municating with the iLEARN Door Control.
Check the physical condition of the Gate iDRIVE Control PLC that is not communicating with the iLEARN Sys-
tem. Replace if damaged. Restart the Gate iDRIVE Control Unit.
See “The iDRIVE CANbus Network fails to initialize or drops out after a short period of operation” un-
der Issues at Initial Start-Up or after System Re-start above.
17
GATE_ERROR__GENERAL_FAULT -
Error 17 occurs when the Gate iDRIVE PLC has set the Gen-
eral Fault bit.
18
GATE_ERROR__CURTAIN1_FAULT -
When the Gate iDRIVE.G does not see a Light Curtain output
as expected during the light curtain test, the iDRIVE.G reports a light curtain error bit (1.3.50 Gate Status Bits
#1 position 04) which is reported as “Light Curtain Error #18. The general causes for this Error are: (1) electri-
cal power interruption during the Light Curtain Test, or (2) the light curtain is blocked during the light curtain
test.
Courion’s iSYSTEM performs the following light curtain test when the Car Gate is given a “CLOSE” command:
1. The Gate iDRIVE.G Expansion Module opens (turns off) the Light Curtain Test Relay, causing the Light
Curtain Test LED on the Expansion Module to go off and the NC relay circuit is open.
2. The Gate iDRIVE.G waits up to 0.5s for both the LC #1 and LC #2 inputs on the iDRIVE.G VFD Controller
to go low.
3. If 0.5s is exceeded and both inputs are not low, then the cycle is interrupted, the LC error bit is set (causing
Error 18 to be reported), and the iDRIVE.G waits for the iLEARN to remove the close command.
4. If both LC inputs are low in the 0.5s period, then the LC Test Relay is again closed (Light Curtain Test LED
on the Expansion Module should go on).
5. The iDRIVE.G waits up to 1.5s for both the LC#1 and LC #2 inputs to go high.
6 If 1.5s is exceeded and both inputs are not high, then the cycle is interrupted, the LC error bit is set (causing
Error 18 to be reported), and the iDRIVE.G waits for the iLEARN to remove the close command.
7. If both inputs are found high in the 1.5s period, then the Car Gate begins to close.
19
GATE_ERROR__CURTAIN2_FAULT -
Same as Error 18 except applies to second light curtain (when
appliecable).
20
GATE_ERROR__LOCKED_OUT -
See Error 13 - DRIVE_ERROR__LOCKED_OUT
Summary of Contents for iDRIVE
Page 8: ...8 ver 071217 2 10 iLEARN System Manual PA PAE INTERLOCK PO 70 3A...
Page 14: ...14 ver 071217 2 10 iLEARN System Manual iLEARN Door Control...
Page 19: ...19 ver 071217 2 10 iLEARN System Manual...
Page 20: ...20 ver 071217 2 10 iLEARN System Manual...
Page 36: ...36 ver 071217 2 10 iLEARN System Manual iDRIVE VFD Floor Control...
Page 38: ...38 ver 071217 2 10 iLEARN System Manual iDRIVE G Car Top Control...
Page 41: ...41 ver 071217 2 10 iLEARN System Manual...
Page 63: ...63 ver 071217 2 10 iLEARN System Manual Doors Closing Doors Opening...