54
ver.071217-2.10
iLEARN
System Manual
iLEARN Door Control Menu - Supplement
Diagnostics
- 1.3 Door Monitor and 1.4 Gate Monitor
1.3.16/1.4.12 Motor PWM Frequency -
This is the motor PWM frequency in Hz. It is pres-
ently set to 12kHz.
1.3.17/1.4.13 Motor Min Frequency
- This is the minimum allowable motor frequency usable
by the internal controller and is presently set to 0 Hz (or 0%).
1.3.18/1.4.14 Motor Min Amp -
This is the minimum allowable motor voltage usable by the
internal controller and is presently set to 100% to support operation with torque motors.
1.3.19/1.4.15 Motor Midpoint Frequency -
This is the midpoint motor frequency used by the
internal controller and is presently set to 30 Hz (or 50%).
1.3.20/1.4.16 Motor Midpoint Amp -
This is the midpoint motor voltage used by the internal
controller and is presently set to 100% to support operation with torque motors.
1.3.21/1.4.17 Motor Max Frequency
- This is the maximum allowable motor frequency us-
able by the internal controller and is presently set to 60Hz (or 100%).
1.3.22/1.4.18 Motor Max Amp -
This is the maximum allowable motor voltage usable by the
internal controller and is presently set to 100% to support operation with torque motors.
1.3.23/1.4.19 Motor Frequency ROC -
This is the frequency rate of change. It controls how
rapidly the motor’s frequency command changes. 100% represents a rate of change of 60Hz
per second. It is presently set to 100%.
1.3.24/1.4.20 Motor Frequency Cmd -
This is the frequency at which the motor controller is
presently being requested to run.
1.3.25/1.4.21 Motor Frequency -
This is the actual frequency at which the motor inverter is
being commanded to run. It is normally the same as “Mtr Freq Cmd” but may be different
during acceleration or deceleration.
1.3.26/1.4.22 Motor Current -
Instantaneous vector sum of three motor phase currents. Val-
ue will not be steady and is only used for peak value over-current detection and protection.
1.3.27/1.4.23 Bus Voltage -
This is the instantaneous DC bus voltage. It will be approxi-
mately 1.4 times the AC voltage input (~290V for 208VAC in, ~320 for 230VAC in).
1.3.28/1.4.24 Peak Bus Voltage -
This is the peak value to date of the instantaneous bus
voltage.
Summary of Contents for iDRIVE
Page 8: ...8 ver 071217 2 10 iLEARN System Manual PA PAE INTERLOCK PO 70 3A...
Page 14: ...14 ver 071217 2 10 iLEARN System Manual iLEARN Door Control...
Page 19: ...19 ver 071217 2 10 iLEARN System Manual...
Page 20: ...20 ver 071217 2 10 iLEARN System Manual...
Page 36: ...36 ver 071217 2 10 iLEARN System Manual iDRIVE VFD Floor Control...
Page 38: ...38 ver 071217 2 10 iLEARN System Manual iDRIVE G Car Top Control...
Page 41: ...41 ver 071217 2 10 iLEARN System Manual...
Page 63: ...63 ver 071217 2 10 iLEARN System Manual Doors Closing Doors Opening...