57
ver.071217-2.10
iLEARN
System Manual
iLEARN Door Control Menu Screens
(continued)
1.5.2 Front Gate Comms
- This is the number of good command/reply transactions between
the iLearn and this Gate PLC in the last second. Approximately 240 transactions per second
are shared by all slaves on the network. For example, if there are 6 door openings and 2 car
gates, this number would be around 30 for a noise free network.
1.5.3 Rear Gate Status -
Same as “Front Gate Status” above.
1.5.4 Rear/Good Comms -
See “Front/Rear Good Comms”.
Diagnostics
- 1.6 System Monitor
1.6.3 CAN Loop Back -
For factory testing only.
1.6.4 USB Echo -
For factory testing only.
Diagnostics
- 1.8 I/O Monitor
- Used for Factory Testing
Door & Gate Parameters
- 3.8 Motor Parameters and 4.0 Gate Parameters
These are parameters to be adjusted ONLY at the factory. They include Motor Minimum Fre-
quency, Motor Minimum Amps, Motor Midpoint Frequency, Motor Midpoint Amps, Motor Maxi-
mum Frequency, and Motor Maximum Amps. These parameters are protected by a Passcode
- Call COURION for additional information.
4.10 PLC Slowdown Code -
Default = 4. This is the distance away from FULL OPEN and
FULL CLOSE where the car gate speed will change from “Fast” to “Slow”, as set by the Gate
iDRIVE.G. 4 = approximately 12”; each increment of 1 = approximately 2”.
Summary of Contents for iDRIVE
Page 8: ...8 ver 071217 2 10 iLEARN System Manual PA PAE INTERLOCK PO 70 3A...
Page 14: ...14 ver 071217 2 10 iLEARN System Manual iLEARN Door Control...
Page 19: ...19 ver 071217 2 10 iLEARN System Manual...
Page 20: ...20 ver 071217 2 10 iLEARN System Manual...
Page 36: ...36 ver 071217 2 10 iLEARN System Manual iDRIVE VFD Floor Control...
Page 38: ...38 ver 071217 2 10 iLEARN System Manual iDRIVE G Car Top Control...
Page 41: ...41 ver 071217 2 10 iLEARN System Manual...
Page 63: ...63 ver 071217 2 10 iLEARN System Manual Doors Closing Doors Opening...