60
ver.071217-2.10
iLEARN
System Manual
nect to the Otis Control and may depict a portion of an older door control with switches and wiring no
longer required.
Follow the Wiring Schematics provided by Courion to wire the Courion equipment
in the hoist-
way and on the car top. Proper Courion Wiring Schematics will have a Revision number beginning
with the designation OTIS in the title block.
WIRE PROVIDED BY COURION
The Courion equipment requires only a 4-wire CANbus cable, a one (1) wire addressing line, and
three (3) 230VAC power wires coming from the machine room. The Courion wiring bundle and Trav-
eling Cable include thirteen (13) additional wires labeled DCxx, DCAxx, DLxx, DLAxx, GCxx, and
SCxx, which can be used for wiring the Door Closed, Door Locked, Gate Contact, and Safety Contact
(Emergency Exit) if desired. The wiring of these contacts must be as instructed on the Otis Elevator
Control Schematics. These wires do not connect to the Courion Door Control System, and are not
necessary for door operation.
SOFTWARE VERSION
The Courion iLEARN Control software must be at least version 3.03.
INITIAL SETUP
Run the COURION iLEARN Setup Wizard, including Gate Setup,
BEFORE
making your Otis Control/
iLEARN Control Interconnections. If the interconnections are already in place, disconnect the ODC
(OTB 3) and CDC (OTB 4) wires from the Courion iLEARN Terminal Block in the Courion Control box.
The Open and Close commands may be simulated by momentarily jumping OTB 1 to OTB 3 for DO,
and OTB 1 to OTB 4 for DC on the Courion Control Terminal Block during the Gate Setup portion of
the Setup Wizard. The DED input (OTB 5) does not need to be high to set up the Courion doors.
COURION HOISTWAY AND CAR TOP NOTES
STOP BUTTON
- Because all standard push buttons are wired to the Otis Elevator Control, the STOP
input on each door and gate iDRIVE needs to be jumped high.
EMERGENCY UNLOCKING DEVICE (EUD)
- At every floor there is an EUD input on the iDRIVE.
This is for the Emergency Unlocking Device (Pull Chain Box). If an EUD is present, there will be a
switch located either in the Interlock (P Style) or in the EUD itself (Q Style). This switch should be
wired to the EUD input and should drop if the device is used to unlock the hoistway doors. If there is
no EUD at a floor, the EUD input must be jumped.
GATE REVERSING EDGE AND LIGHT CURTAINS
- Car Gate Reversing Edges and Light Curtains
wire to the Courion Car Top Control. Remember to remove the jumper in the Light Curtain Power
Summary of Contents for iDRIVE
Page 8: ...8 ver 071217 2 10 iLEARN System Manual PA PAE INTERLOCK PO 70 3A...
Page 14: ...14 ver 071217 2 10 iLEARN System Manual iLEARN Door Control...
Page 19: ...19 ver 071217 2 10 iLEARN System Manual...
Page 20: ...20 ver 071217 2 10 iLEARN System Manual...
Page 36: ...36 ver 071217 2 10 iLEARN System Manual iDRIVE VFD Floor Control...
Page 38: ...38 ver 071217 2 10 iLEARN System Manual iDRIVE G Car Top Control...
Page 41: ...41 ver 071217 2 10 iLEARN System Manual...
Page 63: ...63 ver 071217 2 10 iLEARN System Manual Doors Closing Doors Opening...