ELECTRICAL SPECIFICATIONS (AC OPERATED MODEL)
The cover requires a dedicated single phase 115 VAC power supply (North America).
The cover must be installed in accordance with and comply with all applicable local codes and regulations. All
wiring and connections should be performed by a certified electrician.
Wires and cables should be sized according to local codes and regulations.
NORTH AMERICAN REQUIREMENTS (AC OPERATED)
Voltage
115 V, 60 Hz (1 hot, 1 neutral, 1 ground)
GFCI
15 A single-pole GFCI (not included)
Continuous current draw
3 A Maximum
WARNING
Covana does not allow any modifications to the electrical system. Covana reserves the right to void the warranty
if any modification is done without its approval.
ELECTRICAL SPECIFICATIONS (BATTERY OPERATED MODEL)
Voltage
24 VDC System
Wall outlet voltage
115 VAC for charger North America (230 VAC European model)
Battery
24 V DC, 12 Ah, AGM sealed lead-acid battery
OPERATION LIMITATIONS
WARNING
The cover should never be used if the following conditions are reached.
Maximum wind
Gusts of 25 mph (40 km/h) while in the raised position and 37 mph (60 km/h)
when completely lowered on the spa.
Maximum weight on the cover
(evenly distributed)
200 lb. (90 kg)
NOTE
The load specification for the cover is a provision for environmental outcomes, typically some snow or damp
leaves that could accumulate on the cover.
243462
OWNER'S MANUAL
REVISION 2
Summary of Contents for LEGEND COVER
Page 1: ......
Page 2: ......
Page 16: ...page 14 LEGENDX COVER FIGURE 14 BATTERY SPECIFICATION LABEL 243462 OWNER S MANUAL REVISION 2...
Page 29: ...LEGENDX COVER page 27 HARDWARE IDENTIFICATION TABLE BAGS 243462 OWNER S MANUAL REVISION 2...
Page 70: ......
Page 74: ...page 72 LEGENDX COVER 243462 OWNER S MANUAL REVISION 2...
Page 82: ...page 80 LEGENDX COVER 243462 OWNER S MANUAL REVISION 2...