OASIS COVER
ELECTRICAL WARNING
WARNING
l
To reduce the risk of electrical shocks, the
green-colored terminal (or the terminal marked
“g,” “gr,” “ground,” “grounding” or with a
symbol) that is located inside the supply
terminal box or compartment must be connected
to the grounding connection provided in the
electric supply service panel with a continuous
copper wire equivalent in size to the circuit
conductors supplying the equipment.
l
Two lugs marked “bonding lugs” are provided on
the external surface or on the inside of the
supply terminal box or compartment. To reduce
the risk of electric shock, connect the local
common bonding grid in the area of the cover.
Use terminals with an insulated or bare copper
conductor not smaller than No. 6 AWG (4.11
mm / 13.30mm
2
).
l
All field- installed metal components, such as
rails, ladders, drains or other similar hardware,
within 10 ft (3 m) of the spa must be bonded to
the equipment grounding bus with copper
conductors not smaller than No. 6 AWG (4.11
mm / 13.30mm
2
). (NEC art. 680).
241146
OWNER'S MANUAL
REVISION 1