background image

18

MEMO

Summary of Contents for AM-1012AD

Page 1: ...AM 1012AD ED BD AIR WASHER User s manual English Before operating the product please read this manual thoroughly and retain it for future reference...

Page 2: ...tatus via LED indicators Also water level indicator informs you to stop filling the water They will be helpful for you to understand and use your product s functions Efficient air treatment system AM...

Page 3: ...mbustible materials are used or stored Do not insert sharp objects such as a gimlet into the pollution sensor If the product produces a strange noise burning smell or smoke unplug it from the electric...

Page 4: ...o not cover cord with throw rugs runners or similar coverings Do not route cord under furniture or appliances Arrange cord away from traffic area and where it will not be tripped over Suitable for use...

Page 5: ...COMPONENTS Outer Inner view AM 1012AD ED Water level indicator Water filling opening Air outlet cover Indicators buttons Air inlets Pre filter Top cover Power Cord Humidifying disc Water capacity fil...

Page 6: ...UCT COMPONENTS Outer Inner view AM 1012BD Water level indicator Water filling opening Air outlet cover Indicators buttons Air inlets Top cover Power Cord Humidifying disc Water capacity fill line Wate...

Page 7: ...as per the following 1hr 2hr 4hr 8hr If the off timer is cancelled all indicator lamps are turned off 5 Ionizer button AM 1012ED Use it to activate ionizer The indicator is ON OFF when you touch this...

Page 8: ...ed The airflow speed settings are as per the following Level 1 Level 2 Level 3 3 Off timer button Use it to activate the AUTO OFF mode The AUTO OFF modes are as per the following 1hr 4hr 8hr If the of...

Page 9: ...des an anti bacterial effect Stores 4 5 L of water 2 Humidifying disc A permanent rotating disc sits in the base of the humidifier and absorbs water A fan then blows the dry air in the room through th...

Page 10: ...g the off timer function you can select 1 2 4 or 8 hours AM 1012AD ED or 1 4 or 8 hours AM 1012BD to use the product for desired time To cancel an off timer press the off timer button until the off ti...

Page 11: ...n the refill indicator is on Choose either A or B to refill the water A Pour the water through water filling opening Stop filling the water when you see FULL on the water level indicator B Detach the...

Page 12: ...brasives Cleaning water tank and humidifying disc daily 1 Detach the top cover 2 Separate the humidifying disc from the water tank and clean the water tank and disc with a damp soft cloth and neutral...

Page 13: ...ith water depending on the level of contamination 4 Install the pre filters after completely removing any moisture Push them until it clicks in place Always unplug the product before cleaning the filt...

Page 14: ...ch the ionizer set as image b 3 a Pull out the ionizer from its cover b Clean the two pins of ionizer with enclosed cleaning brush 4 a Push in the ionizer to its cover until it clicks b Place the ioni...

Page 15: ...Close the top cover b Place the air outlet cover and aroma kit in place The actual exterior design of ionizer set may be differ from this user s manual The change may occur to improve the product per...

Page 16: ...zation humidification type varies depending on the surrounding temperature or humidity Therefore if the humidity is high or the temperature is low the amount of moisture supplied by the humidification...

Page 17: ...ilters then clean the pre filter A bad smell is emitted by the air outlet Did you clean the water tank Check the last date of cleaning water tank then clean the water tank Refill indicator blinks Fill...

Page 18: ...ices Power is cut off when the top cover is opened Installation location Indoor use Maximum humidification capacity AM 1012AD ED 450 ml h AM 1012BD 360 ml h Dimensions 312 mm W x 312 mm D x 409 mm H W...

Page 19: ...18 MEMO...

Page 20: ...AM 1012AD ED AM 1012AD ED AM 1012ED 1 1 2 4 AM 1012AD ED 4 AM 1012BD 5 AM 1012AD ED 6 AM 1012BD 7 8 09 10 15 16 17 WARRANTY CARD 19 1...

Page 21: ...2 220 240 50 60...

Page 22: ...3 20 30 60 2...

Page 23: ...4 AM 1012AD ED...

Page 24: ...5 AM 1012BD...

Page 25: ...6 1 5 4 6 2 3 1 2 3 4 AM 1012ED 5 AM 1012AD ED 1 2 3 1 2 3 4 1 2 4 8 5 AM 1012ED 4 20 40 60 6...

Page 26: ...7 AM 1012BD 1 2 1 2 3 3 1 4 8 1 2 3 1 3 2 1 2 3...

Page 27: ...012AD ED 1 AM 1012AD ED 2 AM 1012AD ED AM 1012AD ED BD AIR WASHER User s manual English Before operating the product please read this manual thoroughly and retain it for future reference AM 1012AD ED...

Page 28: ...9 AM 1012AD ED BD 1 2 3 AM 1012AD ED AM 1012AD ED AM 1012AD ED BD 1 2 4 8 AM 1012AD ED 1 4 8 AM 1012BD 1 2 3...

Page 29: ...10 2 AM 1012ED A FULL B...

Page 30: ...11 1 2 3...

Page 31: ...12 AM 1012AD ED 2 4 1 2 3 4...

Page 32: ...13 AM 1012ED 2 1 2 a b b 3 a b 4 a b b b b 1 2...

Page 33: ...14 5 a b...

Page 34: ...15 50 CA...

Page 35: ...16 220 50...

Page 36: ...AM 1012AD ED BD 220 240 50 60 56 2 AM 1012AD ED 450 ml h AM 1012BD 360 ml h 312 312 409 AM 1012AD ED 6 3 AM 1012BD 6 0 This product is designed for Russian power standard 220V 50HZ 17...

Page 37: ...18...

Page 38: ...igations other than those specifically identified in the preceding section COWAY is not responsible or liable for personal injury or property damage of any kind even if arising from a breach of this W...

Page 39: ...tten approval of COWAY c The OWNER has notified COWAY in writing of any failure of the Product covered by this Warranty within thirty 30 days following such failure d There has been no misuse abuse or...

Page 40: ...Made in Korea www coway com 0000000 001...

Reviews: