7
Check your local building codes for the proper method of installation. In the absence of local codes, this unit
should be installed in accordance with the
National Fuel Gas Code No. Z223.1-1998 USA
or
CAN/CGA-B149.1/.2
Natural Gas/Propane Code (Canada)
latest edition or the
National Electrical Code ANSI/NFPA No. 70
or the
Canadian Electrical Code CSA C22.1, 1990
or latest version.
-
Before installing built-in side burners onto a cart, copy all product information such as model number, serial
number and type of side burner (e.g. natural gas or LP) and store information in a safe place.
-
If the side burner is installed by a professional installer or technician, be sure that he or she shows you
where your gas supply shut-off is located. All gas lines must have a shut-off that is readily and easily
accessible. If you smell gas, check for gas leaks immediately. Check only with a soap and water solution.
Never check for gas leaks with an open flame.
Notice:
We strongly recommend professional installation of your Coyote side burner. These instructions provide
the measurements necessary to construct a masonry structure to house your outdoor gas side burner.
IMPORTANT:
Gas fittings, regulator, and installer supplied shut-off valves must be easily accessible.
LOCATION OF YOUR SIDE BURNER:
Locate the side burner only OUTSIDE in a well-ventilated area.
Never locate the side burner in a building, garage,
breezeway, shed or other such enclosed areas without an approved ventilation system
. When in use, the side
burner will generate a lot of smoke. When installing your side burner, select an outdoor location that will ensure
there is adequate area for the smoke to dissipate IN ORDER TO AVOID INHALATION OF POTENTIALLY TOXIC
FUMES.
Ventilation Requirements for Proper Operation of your Coyote Side burner
•
Ventilation for a gas side burner is absolutely mandatory to ensure that your side burner performs as
intended and to ensure the safety of you, your family, and guests. Proper ventilation is necessary to
allow heat inside your side burner to escape and also to allow any gas that has leaked from a tank or
connection to escape before a buildup of such gas can occur and possibly ignite.
Failure to provide proper ventilation will nullify Coyote’s warranty and will
cause a risk of bodily injury or death.
High Elevation Installation and Use
Coyote Side burners are designed to operate most efficiently at 0-2000 feet above sea level. From 2000-4000 feet
above sea level you will not notice any substantial decrease in your heat, although more gas is combusting within the
burners due to less oxygen. Above 4000 feet, you may experience longer cooking times on your side burner than
experienced at sea level. This is due to the air/fuel mixture taking place within the burners. If you have questions or
concerns regarding your location or elevation, please contact Coyote Customer Service for assistance.
Locating the Grill