3
Make sure that the following items are included:
- Hood
- Hood mounting bracket (taped inside the hood)
- 10” round adapter (taped inside the hood)
- Installation manual
- Bag of parts including: 1 wire clamp, 3 waterproof wire connectors, 14 no. 10-12 x 2½” screws, 4 no. 8-18 x 3/8” screws, 10 washers,
1 suction cup (contains more parts than required to perform the installation). (Taped inside the hood.)
Parts sold separately:
- Blower assembly model C1BLOW1200
- Decorative flue:
- Part no. C1FLUE8 for ceilings 8' to 8.5' high
- Part no. C1FLUE10 for ceilings 8.5' to 9.5' high
- Part no. C1FLUE12 for ceilings 9.5' to 12' high
These range hoods must be installed with the C1BLOW1200 blower (sold separately). Do not substitute for an other blower.
Plan where and how the ductwork will be installed. A straight, short duct run will allow the hood to perform most efficiently. Refer to
illustrations below to locate duct opening.
Install 10-inch ductwork, elbows (if needed) and roof or wall cap. Connect metal ductwork to the cap and work back towards the hood
location. Use 2" metal foil duct tape to seal the joints.
Run 3-wire power supply cable to installation location.
The hood must be installed at least 36’’ above the cooking surface.
HH0275A
HOOD
ROOF CAP
WALL
CAP
10” ROUND DUCT
36” ABOVE COOKING SURFACE
10” ROUND ELBOW
WARNING
!
The power cable must be a GFCI protected branch circuit.
WARNING
!
When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and gloves.
This range hood is not designed for use with a charcoal grill.
CAUTION
This range hood is intended for outdoor covered patio or lanai area. As with all electric appliances, this unit must
be protected from the effects of weather.
HK0282A
30”
17 15/16” (36” hood)
20 15/16” (42” hood)
23 15/16” (48” hood)
6 1/4”
C
L
1. PREPARE THE INSTALLATION
2. INSTALL THE DUCTWORK AND ELECTRICAL WIRING