background image

 

- 6 - 

ATTENTION 

■ 

To minimize shock and fire hazards, be sure not to overload outlet. Please 
designate one outlet for your unit. 

■ 

Do not use extension cords. 

■ 

Do not put your hands under the unit when the unit is required to be moved. 

■ 

When the unit is not in use for a long period of time, please unplug the unit 
from the outlet. 

■ 

After unplugging the unit, wait at least 10 minutes before re-plugging it. 
Failure to do so could cause damage to the compressor. 

 

UNPLUG CORD 

■  

To minimize shock and fire hazards, please do not plug or unplug the cord 
with wet hands. 

■  

During maintenance and cleaning, please unplug the unit. 

 

PROPER GROUDING REQUIRED 

■ 

To minimize shock and fire hazards, make sure that the unit is properly 

grounded. 

 

PROHIBITION 

■ 

Do not attempt to remove or repair any component unless instructed by 
factory. 

■ 

Make sure that the unit is not resting on or against the electrical cord and 
plug. 

■ 

To minimize personal injury, do not hang on the doors. 

■ 

Do not store any flammable and explosive gas or liquids inside the unit. 

■ 

Do not attempt to alter or tamper with the electrical cord. 

!

 

 

REGULAR MAINTENANCE 

 

 

CLEANING THE CONDENSER COIL 

  For efficient operation, it is important that the condenser surface be kept 

free of dust, dirt, and lint. 

  We recommend cleaning the condenser coil and fins at least once per 

Summary of Contents for COAR

Page 1: ... 1 Outdoor and Indoor Electric Refrigerator Model COAR USER S MANUAL COAR PLEASE READ THE MANUAL THOROUGHLY PRIOR TO EQUIPMENT SET UP OPERATION AND MAINTENANCE ...

Page 2: ...ging the unit in Please read through the manual in its entirety CABINET LOCATION GUIDELINES Install the unit on strong and leveled surfaces Unit may make unpleasant noises if surface is uneven Unit may malfunction if surface is uneven Install the unit in a dry well ventilated area For best performance please maintain clearance of 6 on the back of the unit and at least 4 clearance on the sides of t...

Page 3: ...ion Quantity 1 Cabinet 1 2 Upper Shelf 2 3 Glass Shelf 1 4 Basket 1 5 Shelf Support Clip 8 6 Glass Shelf Protective Pad 4 7 Shelf Bracket 4 8 Slide Set 1 9 Caster 2 10 Level Adjuster 2 11 Door Gasket 1 12 Door Key 2 13 Upper Hinge 1 14 Bottom Hinge 1 ...

Page 4: ...e alternate upper hinge that came with the unit when purchased on the alternate top corner To remove the upper hinge you will need to remove the six screws on the Control Panel to gain access to the hinge In regards to the bottom hinge you just need to remove the three bolts that are holding this hinge to the refrigerator and re locate it to the new side The bottom hinge is universal while the top...

Page 5: ...is displayed in ºF When LED2 is off the temperature is displayed in ºC Restoring to Default Settings Press twice and then put your fingers on for 6 seconds When the display light blinks it means all settings have been reset It will return to normal status in 6 seconds ELECTRICAL Please ensure that the required voltage of the compressor is being supplied at all times Low or high voltage can detrime...

Page 6: ...hands During maintenance and cleaning please unplug the unit PROPER GROUDING REQUIRED To minimize shock and fire hazards make sure that the unit is properly grounded PROHIBITION Do not attempt to remove or repair any component unless instructed by factory Make sure that the unit is not resting on or against the electrical cord and plug To minimize personal injury do not hang on the doors Do not st...

Page 7: ...d replace Check door gaskets for proper seal after they are replaced Periodically remove the shelves and pilasters from the unit and clean them with mild soap and warm water To remove the pilasters first remove the shelves and shelf brackets Then simply lift the pilaster up and out WARNING Disconnect power cord before cleaning any parts of the unit TROUBLE SHOOTING Before requesting any service on...

Page 8: ...r coil iced over Set thermostat to lower temperature Re arrange product to allow for proper air flow Make sure there is at least four inches of clearance from evaporator Allow adequate time for product to cool down Replace fuse or reset circuit breaker Clean the condenser coil Ensure doors are closed when not in use Avoid opening doors for long periods of time see above Cabinet is noisy Loose part...

Page 9: ...ipt of the damaged parts and to Coyote s satisfaction if the original part is proven defective Coyote may elect to approve the claim and issue a replacement part without charge This warranty does not cover any failures or operating difficulties due to abuse accident misuse alteration misapplication vandalism maintenance improper installation operation or service as stated in this manual Furthermor...

Reviews: