background image

 

 

 

2. Error Codes and description 

2.1    Error Message will be displayed when Malfunction 

ON/OFF: 

KNEAD + TAP + POWER

(buttons on the controler), press and hold the three buttons in two senconds to turn on the 

automatic analysis system model. 

After activating the "auto-checking model",    the display screen of the controller keeps flashing;    if there is something wrong with 

the chair, the time area will show you the exact code of the malfunction, meanwhile the buffer will make noise. 

ERR Code 

Phenomenon 

Malfunction description 

Solutions 

Remarks 

 

remote control tested any 

key pressed more than 25 

seconds 

one of the KEY has been 

blocked 

check the key of the remote 

control 

turn on the chair 

 

remote control did not 

connected 

the remote control wire is 

broken or the remote control 

wire is disconnected 

reconnecte the remote 

control wire or change the 

remote control wire. 

turn on the chair 

 

backrest signal is abnormity 

1.backrest wire(black) is not 

well connected. 

2.up & down limit sensor is 

broken 

1.check whether the backrest 

wire(black) is well 

connected 

2.change the up & down limit 

sensor 

turn on the chair 

 

backrest signal is abnormity 

1.backrest wire(black) is not 

well connected. 

2.the counting sensor of the 

rolling motor is broken 

1.check whether the backrest 

wire(black) is well connected 

2.change the counting sensor 

of the rolling motor 

activate the 

Rolling function 

 

tested more than 2 wideth 

inspection signal 

1.wideth inspection board is 

broken 

2.wideth inspection wire is not 

well connected 

1.change wideth inspection 

board 

2.change backrest 

wires.(black) 

activate the 

Rolling function 

 

more than 5 seconds did 

not tested the wide signal 

1.wideth inspection board is 

broken 

2.the wire connect to the 

wideth inspection board is 

disconnected 

3.kneading motor is broken or 

kneading belt is lost 

1.change wideth inspection 

board 

2.change backrest 

wires.(black and gray) 

3.change kneading motor 

activate 

auto-check 

model 

 

more than 5 seconds did 

not tested the middle signal 

1.wideth inspection board is 

broken 

2.the wire connect to the 

wideth inspection board is 

disconnected 

3.kneading motor is broken or 

1.change wideth inspection 

board 

2.change backrest 

wires.(black and gray) 

3.change kneading motor 

activate 

auto-check 

model 

Reviews: