background image

 

after tested signal from 

down limit sensor then 

tested signal from up limit 

sensor in 2 seconds. 

.upper limit sensor is broken. 

.change upper limit sensor 

activate 

auto-check 

model 

 

can't test signal from foot 

rest recline actuator 

1.foot rest recline actuator is 

broken 

2.foot rest actuator motor wire 

is disconnected 

3.the signal wire of foot rest 

actuator is disconnected. 

1.change foot rest recline 

actuator 

2.check whether the foot rest 

recline actuator motor wire is 

well connected. 

3.check whether the signal 

wire of foot rest actuator is 

well connected 

activate 

auto-check 

model 

 

 

test signals from front 

sensor and rear sensor at 

the same time. 

1.the 6 core signal wire is 

disconnected. 

2.up & down limit sensor of 

the foot rest are broken 

1.check whether the 6 core 

signal wire is well connected. 

2.change up & down limit 

sensor of the foot rest. 

activate 

auto-check 

model 

 

didn't test signal from front 

sensor of the footrest more 

than 20 seconds. 

1.the down limit sensor of the 

foot rest is broken 

2.foot rest extending motor is 

broken or disconnected 

1.change down limit sensor of 

the footrest 

2.change the footrest 

extending motor or check 

whether the motor wire is 

well connected. 

activate 

auto-check 

model 

 

After tested front sensor 

signal, then tested front 

sensor signal in 2.5 

seconds. 

the upper limit sensor of foot 

rest is broken 

change the upper limit sensor 

of the footrest. 

activate 

auto-check 

model 

 

didn't tested rear sensor 

signal in 20 seconds 

1.the upper limit sensor of 

foot rest is broken 

2.foot rest extending motor is 

broken or the motor wire is 

disconnected. 

1.change upper limit sensor 

of the foot rest. 

2.change foot rest exteding 

motor 

activate 

auto-check 

model 

 

 

After tested rear sensor 

signal, then tested front 

sensor signal in 2.5 

seconds. 

the lower limit sensor of the 

foot rest is broken 

change footrest lower limit 

sensor 

activate 

auto-check 

model 

 

 

 

 

 

 

    when start the backrest 

recline actuator, there is no 

counting signal for more 

than 2.5 seconds 

1.backrest recline actuator is 

broken 

2.backrest recline actuator 

wire is disconnected 

3.the signal wire of the 

backrest recline wire is 

disconnected 

1.change backrest    recline 

actuator 

2.check whether the backrest 

recline actuator motor wire is 

well connected. 

3.check whether the signal 

wire of the backrest recline 

actuator is well connected 

activate 

auto-check 

model 

Reviews: