when start the zero-gravity
actuator, there is no
counting signal for more
than 2.5 seconds
1.Zero-gravity actuator is
broken
2.zero-gravity actuator wire is
disconnected.
3.the signal wire of
zero-gravity actuator is
disconnected
1.change zero-gravity
actuator
2.check whether the
zero-gravity motor wire is
well connected.
3.check whether the signal
wire of zero-gravity
actuator is well connected
activate
auto-check
model
2.2 Common Troubles and Maintenance Methods are listed as following:
Serial NO.
Phenomenon
Description
Maintenance Methods
01
No Function When
Starting.
The LCD isn’t illuminating:
①
Fuse melts (in the Power Source Box or on
the transformer wire).
②
Power supply circuit poorly connected.
③
main PCB fails.
①
Replace Fuse.
②
Replace Power Box.
③
Replace main PCB.
02
No function when
starting.
The LCD is illuminating
:
①
Mechanical switch fails or it’s wire is
opened.
②
Up or Down Stroke Photo-electricity fails.
③
Main PCB fails.
④
Kneading is on without pressing any key
when starting and no response by pressing
other keys.
①
Replace mechanical switch or
it's wire.
②
Replace Stroke Photo-
electricity.
③
Replace the main PCB.
④
Width Inspection Board of
PCB fails, replace it.
03
No Width
switchover.
①
The terminals of Width Inspection on main
PCB and wires are poorly connected.
②
The terminals of Width Inspection on
massage mechanical and wires are poorly
connected.
③
Width Inspection fails.
④
Main PCB fails.
①
&
②
Plug the terminal securely
or replace the wires.
③
Replace Width Inspection.
④
Replace the main PCB.