Instruction of Safety

 

 

Before you put the chopper into operation, please read this instruction and 
operation manual completly.  
The operation should only be done by qualified personnel. 
The precautions and warnings below must be observed at the operation of the 
chopper. The braking chopper instruction and operation manual do not replace 
the manual of initial operation of the inverter. 

1.1

 

Instructions and Rules 

During installation, general installation regulations such as following should be observed 

DIN VDE 0100

 

General requirements for the installation of power with mains 

VDE 0113

 

General requirements for the installation of electrical equipment for 
production and tooling machines 

VDE 0160

 

Requirements for electronic equipment for use in electrical power 
installations 

VDE 0470

 Part 1 

International protection 

1.2

 

Safety 

 

Caution Danger ! 

Disconnect unit from mains and wait until the capacitors have discharged 
before making any repairs. After the installation make sure that the unit 
and motor is properly grounded in order to avoid electrical hazard. 

Summary of Contents for BC 2.2 Series

Page 1: ...Brake Chopper BC 2 2 4 2 Instruction and Operation Manual...

Page 2: ...done by qualified personnel The precautions and warnings below must be observed at the operation of the chopper The braking chopper instruction and operation manual do not replace the manual of initia...

Page 3: ...nditions 4 2 2 Technical Data Chopper voltage 1000V 4 3 Connections and Indications 5 3 1 Design 5 3 2 Connectiondiagramm 6 4 Example of Connection 7 5 Dimensions 7 6 Options 8 6 1 Overcurrent relay 8...

Page 4: ...class F without condensation 5 85 relative humidity Environment Base standard DIN EN 60068 2 6 Resonance seach Test specification 5 Hz 13 2 Hz 150 Hz 2mm peak to peak 0 7g Installation height h H 100...

Page 5: ...r BUSS connection BUSS voltage inverter R1 R2 a bimetal relay must be connected in series to the braking resistor This has to be adjusted to the nominal current of the brake resistor see Chapter 4 Exa...

Page 6: ...6 Instruction and Operation Manual Misprints and technical changes reserved 3 2 Connectiondiagramm...

Page 7: ...n If cables between inverter and chopper resp chopper and brake resistor are less than 25 cm they have to be twisted and if they are longer than 25 cm they have to be shielded 5 Dimensions Type B B1 H...

Page 8: ...racket for Overcurrent relay Art No 36770 Z2 6 2 Ultrafast semiconductor fuses Use with Braking chopper Fuse value in A A Part No Fuse Art No Fuse Breaker 3pol 12262 0F 50 34606 00 34529 00 12262 1F 6...

Page 9: ...MS brake load PMAX BRAKE in kW peak load brake chopper tBRAKE in seconds brake time tRUN in seconds motoring operation tBRAKE in seconds regen operation tOFF in seconds stop Calculation Brake Resistor...

Page 10: ...10 Instruction and Operation Manual Misprints and technical changes reserved 8 Connection Diagramm option Master Slave...