background image

effigis.com

CPAT FLEX (DRV3 Lite)

7

6

User Manual

2.  System Components

The DRV3 Lite is a portable dual-band signal leakage detection meter designed to operate as 
a find-and-fix meter for all digital and hybrid cable networks.It can operate in “system mode”, 
detecting leakage carriers produced from the DSG1 signal generator located at the head-end 
location, in “pressure test” mode, detecting high-level carriers generated by the DSG1 Lite or 
in “spectrum mode”, working as a simplified spectrum analyzer. The DRV3 Lite is frequency 
agile from 118 to 140 MHz (Mid-band tuner, external antenna) and from 600 to 860 MHz 
(LTE band tuner, internal antenna). It can easily be set up via its intuitive user interface.
This section describes the DRV3 Lite unit in detail including its accessories, feature set,
button usage, powering and data interfaces.

2.1  Initial Verification

Your DRV3 Lite unit is charged, calibrated, and ready to use right out of the box. Upon 
delivery, visually inspect each item for any damage that may have occurred during shipping. 
If you see any signs of physical damage, please contact Effigis:

• Callers from the U.S. and Canada can dial +1-888-495-6577 (toll-free number)
• International callers can dial +1-514-495-0018

If there are no apparent signs of physical damage, turn on the unit by pressing the button, 
approximately three (3) seconds, and make sure the unit boots up properly.
Check that your package contains all ordered items. If you ordered the DRV3 Lite Portable 
Leakage Detection Meter kit, the following items are included:

• DRV3 Lite meter, including its rechargeable battery pack
• Rubber duck antenna for mid-band measurement with SMA connector
• AC adapter
• User Manual

If any of the standard accessories are lost or damaged, you can order a replacement. Please 
quote the following DRV3 Lite part numbers when ordering:

NOTE

This equipment has been tested and found to comply with the limits for a 
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits 
are designed to provide reasonable protection against harmful interference 
when the equipment is operated in a commercial environment. This equipment 
generates, uses, and can radiate radio frequency energy, and if it is not 
installed and used in accordance with the instruction manual, it may cause 
harmful interference to radio communications. Operation of this equipment 
in a residential area is likely to cause harmful interference, in which case the 
user will be required to correct the interference at his own expense.

NOTE

Any modifications made to this device that are not approved by Effigis 
Geo-Solutions Inc. may void the authority granted to the user by the FCC to 
operate this equipment.

1.4  Technical Support

The Effigis Technical Support Service is available from Monday through Friday from 9:00 AM 
to 5:00 PM Eastern Time.
Toll free from U.S. and Canada: + 1-888-495-6577
International: + 1-514-495-0018
Fax questions anytime to: + 1-514-495-4191

cpat@effigis.com

1.5  Calibration

Your DRV3 Lite unit has been calibrated and tested at the factory, and does not need further 
calibration before use.
However, if the unit suffers damage or is repaired, it is recommended that the unit be tested 
by an authorized Effigis service center.
As well, if your company requires regular calibration of all equipment, or requires a 
calibration certificate for the DRV3 Lite, a calibration service is available through Effigis.
For more information on our calibration service, please contact your Effigis representative.

1.6  Effigis Website

The Effigis Web site contains product specifications, information, press releases, brochure 
downloads and Frequently Asked Questions (FAQs). Please visit our Web site at: 

effigis.com 

.

Summary of Contents for DRV3 Lite

Page 1: ...DRV3 Lite User Manual V 1 3 2017 10 03 Part No 100 00009 001...

Page 2: ...Band Parameters 17 3 4 4 LTE Band Parameters 18 3 4 5 Tag Mode 18 3 4 6 Proximity 19 3 4 7 Sound 19 3 4 8 Mode at Startup 19 3 4 9 Units 20 3 4 10 DRV3 Lite Firmware Management 20 This document provi...

Page 3: ...aboratory use EMC requirements Part 1 Generic requirements 1 3 2 Compliance This Class B digital apparatus complies with Canadian ICES 003 2012 This Class B digital apparatus also complies with Europe...

Page 4: ...n order a replacement Please quote the following DRV3 Lite part numbers when ordering NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to P...

Page 5: ...riers produced from the DSG1 signal generator located at the headend When operating in system mode the DRV3 Lite is fully agile from 118 140 MHz Mid band tuner and 600 860 MHz LTE band tuner 3 Spectru...

Page 6: ...e to recharge the battery and power the DRV3 Lite 2 4 4 Data Interface The DRV3 Lite has two data interfaces a Micro B USB connector and an integrated Bluetooth module The USB connection is used for f...

Page 7: ...r User and Password 2 Select Downloads from the Need help button 3 Download the Settings Application DRV3Lite zip file which contains Settings Application DRV3Lite exe and xml files with default confi...

Page 8: ...describes the basic procedures for transferring data to and from the DRV3 Lite and for managing the settings files For detailed information on each parameter please refer to Sections 3 4 With a DRV3 L...

Page 9: ...urn OFF after 1 minute ON Backlight is always ON 3 4 2 Contrast This parameter controls the screen contrast on the DRV3 Lite s display Contrast values varies from 0 least contrast to 9 highest contras...

Page 10: ...with modulation frequencies varying from 20 Hz to 110 Hz You can also adjust the detection sensitivity of the channel tag to allow the DRV3 Lite to discriminate between channel noise and the tag sign...

Page 11: ...and Carrier only Both active Reached Yes on strongest signal detected either band Enabled and tag detected Only one band active Reached Yes on signal in active band other band ignored Carrier only Onl...

Page 12: ...Manual 4 2 Connecting the DRV3 Lite 1 Turn the DRV3 Lite on and the Bluetooth icon appears see section 5 2 2 Open the CPAT Mobile application and enter your username and password There is a offline mo...

Page 13: ...the drop down menu If there is no available DRV3 Lite application shows a red drop down menu Just beside the drop down menu press on Bluetooth refresh icon if you want to find again Bluetooth ready D...

Page 14: ...l connect to selected unit and will show its measurements Application graphic interface colors is different according to current DRV3 Lite mode System or Pressure Test PT 6 Press on top right icon to...

Page 15: ...ere is Bluetooth connectivity the icon appears in black When there is no Bluetooth connectivity the Bluetooth icon appears in white with a black background USB USB logo appears at the same location th...

Page 16: ...irmware updates may be available for the DRV3 Lite The update will be uploaded using the DRV3 Lite Settings Application When a new firmware update becomes available the Effigis support team will plan...

Page 17: ...he unit should be carefully packed so that it will not be damaged in transit when needed appropriate packing materials can be obtained by contacting Effigis s Customer Support Effigis is not liable fo...

Page 18: ...in this Section Limited Warranty and actually fails during the applicable warranty period and under normal use Effigis shall at its sole discretion i repair or replace the non conforming Product to r...

Page 19: ...effigis com 1 888 495 6577 2017 Effigis All rights reserved 006 000064 104...

Reviews: