CXB2
Mexico
7
©
CPI 2016
P/N# 253052002
http://www.cranepi.com
SERVICE BUTTON FUNCTIONS
BELT CLEANING MODE:
To start the belts; press
Service Button
twice (press/pause time is less than 1 sec.).
•
Use a clean damp cloth. Gently press it against the moving belt to clean.
•
To stop cleaning, press Service Button once; otherwise the belt motion will stop in 20 seconds
automatically.
DISPLAY QUANTITY OF UNCREDITED BILLS IN A NOTE CASSETTE:
•
To check the quantity of accepted, BUT un-credited bills in a Note Cassette, press and hold the
Service Button for more than 3 seconds in Idling or Disable state.
•
Count the number of short Blue flashes of the Diagnostic LED. This indicates the number of notes
that are in the cassette for which no credit was issued.
•
This counter will be cleared if the Note Cassette is removed or the power is turned off.
SET BRIGHTNESS OF BEZEL BLUE RUNNING LIGHTS:
•
Turn OFF power to the validator.
•
Switch the unit to Service Mode (SW 8 is ON) and reapply power.
•
Press the Service Button once (less than 1 sec.) to switch between two levels of brightness of the
bezel blue running lights.
•
Switch power off when desired brightness is set, then switch the unit to Working Mode (SW 8 is
OFF) and reapply power.
CLEANING:
The CXB2 series will not need cleaning as often as magnetic sensing Note Validators. If
cleaning is required, use compressed air and a soft cloth moistened with mild, non-abrasive
detergent.
Refer to Repair Manual for more cleaning instructions.
•
Locate the service button on the top of the unit (refer to Figure 5). Depress the button
twice
to enter belt cleaning mode.
•
The belts will run for 20 seconds.
•
Press a damp, soft, cloth moistened with mild, non-abrasive detergent against the belts to
clean.
See Figure 6.
Figure 5
Figure 6
Belts