SERVICE BUTTON FUNCTIONS 

 
 

      BELT CLEANING MODE: 
 

    To start the belts; press 

Service Button

 twice (press/pause time is less than 1 sec.). 

  Use a clean damp cloth. Gently press it against the moving belt to clean. 

  To stop cleaning, press Service Button once; otherwise the belt motion will stop in 20 seconds 

automatically. 

 

    DISPLAY QUANTITY OF UNCREDITED BILLS IN A NOTE CASSETTE:  
 

  To check the quantity of accepted, BUT un-credited bills in a Note Cassette, press and hold the 

Service Button for more than 3 seconds in Idling or Disable state. 

  Count the number of short Blue flashes of the Diagnostic LED. This indicates the number of notes 

that are in the cassette for which no credit was issued. 

  This counter will be cleared if the Note Cassette is removed or the power is turned off.    

 

  SET BRIGHTNESS OF BEZEL BLUE RUNNING  LIGHTS:  
 

  Turn OFF power to the validator. 

  Switch the unit to Service Mode (SW 8 is ON) and reapply power.  

  Press the Service Button once (less than 1 sec.) to switch between two levels of brightness of the 

bezel blue running lights. 

  Switch power off when desired brightness is set, then switch the unit to Working Mode (SW 8 is 

OFF) and reapply power.    

 

CLEANING: 

The CXB2 series will not need cleaning as often as magnetic sensing Note Validators. If 
cleaning is required, use compressed air and a soft cloth moistened with mild, non-abrasive 
detergent.  
Refer to Repair Manual for more cleaning instructions. 

  Locate the service button on the top of the unit (refer to Figure 5). Depress the button 

twice

 to enter belt cleaning mode.  

 

  The belts will run for 20 seconds.  

 

  Press a damp, soft, cloth moistened with mild, non-abrasive detergent against the belts to 

clean. 

 See Figure 6.

 

 

 

 

 

 

 

 

 

 

Figure 5  

 

 

 

 

 

Figure 6 

Belts 

Summary of Contents for CXB2

Page 1: ...ounts on either the existing four mounting studs located in the machine or on the mounting bracket provided in various mounting kits Features of the CXB2 include 20 50 100 200 500 Peso note acceptance...

Page 2: ...http www cranepi com Major Parts Description MDB Harness OPT HS CXB MDB2 Rev D Main Body Assembly SM17 00 000 Vault Assembly BX17 00 000 10 Cassette Lower Guide Assembly SM17 21 000 16 Pin Connector...

Page 3: ...verride the above options and the Note Validator will operate according to switch settings defined in the chart below See Figure 2 2 Set note validator switches to desired settings DIP SWITCHES Mexico...

Page 4: ...nnect the CXB2 to the supplied interface harness Install the 16 pin connector into the interface slot See Figure 4 Caution Do not force the plug into note validator This may cause pins to bend or brea...

Page 5: ...move the notes and check the status Instructions for cassette removal are on the label at the back of the magazine Once the magazine is installed verify that the LED status indicator remains BLUE and...

Page 6: ...LED is steady ON remove the programming stick Cycle the power CX B 1 1 3 4 R 0 Product family name CX B for Bill stacker Electronic platform 1 Standard MDB Bill path width 1 71mm 2 73mm Drop Box capa...

Page 7: ...he Note Cassette is removed or the power is turned off SET BRIGHTNESS OF BEZEL BLUE RUNNING LIGHTS Turn OFF power to the validator Switch the unit to Service Mode SW 8 is ON and reapply power Press th...

Page 8: ...re are two ways to retrieve diagnostic information 1 Diagnostic LED Observe blue Diagnostic LED It will flash to indicate the problem per the diagnostic table below 2 Bezel LEDS When the Bezel LEDS ar...

Page 9: ...upplied to the note validator Steady ON Red 2 chevron bars Comm disabled from mech VMC Note Refer to the diagnostics chart on page 9 and to figure 7 1 Must have product in the vending machine Check co...

Page 10: ...ck Cassette is full 4 red on black Failure of the Stacker mechanism 5 red on black Failure of the Discrete bill path sensors 6 red on black Failure of the Optical Array sensor 7 red on black Failure o...

Page 11: ...CXB2 Mexico 11 CPI 2016 P N 253052002 http www cranepi com Figure 9 Figure 10 cut out area 4 threaded studs 8 32 hight 0 5 Location of threaded studs...

Page 12: ...CXB2 Mexico 12 CPI 2016 P N 253052002 http www cranepi com...

Page 13: ...ublication may be copied transmitted transcribed or distributed in any form or by any means or stored in a database or retrieval system or translated into any language natural or computer without the...

Reviews: