To delete all captured fault sets, press the CANCEL button while in the Fault Log.
To leave the Fault Log, press the MENU button to cycle to the next Menu category or press
either the Line 3 or the Line 4 button to return to the selected meters.
L O C A L
5 : 2 7 A
S T A N D B Y
F A
U
L
T
L
O
G
1 O
F 2
J A N 2 3 4 : 3 7 A
H
I G
H
R
E
F L
R
F F A
U
L
T
If the Fault Log is empty, the following is displayed:
F A U L T L O G
N O R E C O R D E D F A U L T S
B.13.2 Factory Authorized Access Code (FAAC)
Entry of the Factory Authorized Access Code provides entry to the Factory Authorized Access
Mode (FAAM). Upon entering the FAAC and pressing the FUNCTION button, the CHPA will
be in FAAM. This mode provides unlimited read/write access to all data (fault trip points,
special test modes, etc.) until prime power is cycled or the code is reentered.
FAAM is available only through the Local panel. To provide a visual indication that the unit is
in FAAM, the Regulator Bypass LED will flash to indicate which control point(s) are in FAAM.
FAAC entry appears as follows:
L O C A L
6 : 1 1 P
S T A N D B Y
F A A C :
The FAAC is 050401.
To warn the unwary user, the following flashing message (alternating between 37 percent and
100 percent illumination) appears upon entering the FAAM: