Generally speaking, a 0.10 inch H
2
0 pressure drop in a 5-inch-diameter flex-type hose
corresponds to approximately 10 ft in length. It is therefore recommended that for longer duct
runs, a transition be made to perhaps 8-inch duct as near the CHPA exhaust as possible; 8-inch
plumbing will significantly reduce pressure drop and permit much longer duct runs. Use of 4-
inch-diameter ducting should be strictly avoided.
It is highly recommended that a heating, ventilation, and air-conditioning (HVAC) engineer be
consulted before ducting is installed as insufficient cooling will significantly impact TWT
(traveling wave tube) longevity.