6-3
Table 6-1. Preventive Maintenance Schedule CHPA (continued)
Electrical Task
Daily
1 Month
3 Months 6 Months 1 Year
5 Run Performance Tests
X
6 Test Any Spare Tubes
X
Table 6-1 Notes:
1.
Cleaning may be required more or less frequently than shown.
2.
Blower replacement at 40,000 hours of operation.
Table 6-2. Recommended Test and Service Equipment Description
(Listed equipment below may be substituted by any equivalent piece of test equipment.)
Sweep Signal Generator, frequency range HP 8360, 8350 DC to 20 GHz, capable of CW and sweep
operation, compatible with Scalar Analyzer, item.
RF Power Meter complete with power HP 437B, 438A with 8481A Power Head sensors, Type N, 50
Ohms, power measurement range -30 to +20 dBm.
Variable Attenuator 0 to 25 dB, DC to 20 GHz, Merrimac ASM25-11K 50 Ohms.
Scalar Network Analyzers, frequency range HP 8757 with two sensors DC to 20 GHz, complete with dual
detector probes. Should have dual markers, with Delete mode. Compatible with Sweep Signal Generator
(item 1).
RF Splitter, precision 2-way, 50 Ohms, Type N, HP 11667A DC to >20 GHz.
High quality, low loss RF test cables as required for test set up.
Microwave Frequency Counter, 3.DC to 20 GHz.* HP 5340A
*Required only if Sweep Generator is not digitally controlled or phase locked.
Clip-On mA Meter HP 428B Clip-On DC Millimeter 1 mA to 10 A +/- 3%.
Voltmeter-Fluke 8050 DVM 4-digit and Triplett Multimeter.
Couplers Input and Output Coaxial, and Waveguide.
Calibrated Waveguide Coupler Narda, HP, with others. Directional Coupler. Coupling factor 40 dB,
directivity 30 dB.
Dummy Load, 3 kW, Waveline, Narda, etc.
HV Breakout Box, CPI part number 01020673. Adapter Cable Set, part numbers 01020681,01020682.
0– to 60–V, 3-A DC power supply.
Power supply dummy plug, part number 01000474-02.