CHPA SERIES
B-24
THIS
DOCUMENT
IS
THE
PROPERTY
OF
COMMUNICATIONS
&
POWER
INDUSTRIES.
REPRODUCTION
OR
RELEASE
WITHOUT
EXPRESS
PERMISSION
IS
STRICTLY
PROHIBITED
D
OC
.01023245
R
EV
.L
Table B-9. Computer Interface Parameters (continued)
Function Name
Possible Entries
Description
Bad Check Byte
Toggle between YES/NO
Loopback Test
Press ENTER to start (sends “V”); will
display PASS if unit sees itself (receives
“V”), FAIL if it doesn’t. Press ENTER again
or leave this item to stop the test. For the
unit to see itself, loop TX+ to RX+ and TX- to
RX-.
Installation Test
Press ENTER to send a steady stream of
“CHPA” using the user-selected interface
parameters. Press ENTER again or leave
this item to stop the test.
Table B-10. Computer Interface Parameters
Function Name
Possible Entries
Description
Device Address
Numerical entry: 32
10
to 126
10
Baud Rate
Toggle between 9600, 4800,
2400, 1200, 600, 300
Parity
Toggle between Odd, Even,
Mark, None
Protocol
Toggle between ASCII, STX/ETX
Check Byte
Toggle between Long and Sum
If Protocol is set to STX/ETX, then Check
Byte must be Long (short for longitudinal). In
this case, Sum can’t be chosen.
CR Enable
Toggle between YES/NO
LF Enable
Toggle between YES/NO
Bad Check Byte
Toggle between YES/NO