Table 4-1. Helix and RF Settings Ranges (continued)
Fault Name
Minimum
Nominal Factory
Preset Defaults
Label
Maximum
Set for TWT
High RF Alarm
0W
700 W
900 W
Rated
High RF Fault
0W
750W
900W
Rated+5%
High Reflected RF
0 W
50 W
80 W
50W
Helix Voltage
Detected in
Standby
1.00 kV
4.00 kV
7.50 kV
5 kV
4.7 Setting Serial Remote and CIF Port
Parameters
The serial port parameters for both the Remote and CIF (Computer Interface) ports are set
through the front panel. The Remote port can be configured either for use with the CHPA
Remote panel or as a user-configurable port that supports the same protocols and command set
as the CIF port. The CIF port is typically used with a user’s remote computer. These ports are
described in detail in Chapter 3, “Interfaces.”
To change the factory default settings for the Remote port, perform the following steps:
1.
Press the SPECIAL key followed by the (decimal) button.
2.
Key in 18, the display will change to RMT CONFIGURATION.
3.
Repeatedly press the FUNCTION button to review each selection under this menu.
•
If a CHPA Remote panel is to be used with the unit, the entry for PORT TYPE should be
RMTPNL. Use the arrow keys to select this entry. Now, no other entries will appear
under RMT CONFIGURATION and the CHPA is ready to use with the CHPA Remote
panel.
•
If the user configurable port option is desired, set PORT TYPE to USER.
4.
Now, repeatedly press the FUNCTION button to cycle through the serial port and protocol
settings. Use the arrow keys to select the desired settings.
In addition to the parameters set in the above procedures, both ports have hardware settings
that may require adjustments. See Chapter 3, “Interfaces,” for descriptions regarding
termination resistors (both ports) and RS-232 or
RS-422/485 selection (CIF port only).