MPA Hub Mount I&O Manual
Noise Figure
18dB maximum at maximum
gain
Group Delay, Linear
0.01 nsec/MHz over any 60
MHz
Parabolic
0.005 nsec/ MHz2 over any 60
MHz
Ripple
0.5 nsec p-p over any 60 MHz
Residual AM, up to 10KHz -50
dBc
10 to 500KHz
-20(1.5+ log f) dBc
above 500KHz -85 dBc
Phase Noise
Continous Spectrum without
spurs
Offset Frequency
100 Hz
-80 dBc /Hz
1000 Hz
-100 dBc/Hz
10 KHz
-106 dBc/Hz
100 KHz
-110 dBc/Hz
1MHz -125
dBc/Hz
Prime Power
Voltage 100-264VAC
Frequency 47-63
Hz
Power Factor
0.95 GHz
Power
Consumption
1500VA per HPA
Input Connector
Type N Female
Output flange
WR75 Grooved Flange
Remote Serial Connector, J1
KPT07E-12-10S, mate with
Amphenol KPSE06F-12-10P
M&C Connector, J2
KPT07E-16-26S, mate with
Amphenol KPSE06F-16-26P
Operating Temperature
Range
-30 to 55
°
C
Humidity
Up to 100% condensing
Altitude
10,000 ft with adiabatic
derating
Appendix G-4