background image

MAINTENANCE 

 
1)  The collection cup should be emptied regularly.  Every time you empty the cup, clean the base of the  funnel 

and the inside of the throat for better collection. 

 
2) The 

AeroForce 2

TM

 

should be cleaned every three months, or as needed.  

 
3)  Clean the powerheads at least once a month. Replace each powerhead every twelve to eighteen months to 

 ensure optimal performance.

  To clean the powerheads, follow the “Removal and Cleaning of your Powerhead” 

instructions below.   

 

 

 

REMOVAL AND CLEANING OF YOUR POWERHEAD 

 

 

1)  Remove the inner body from the outer body then remove the pump and base plate from the inner body

 

 

2)  Remove the Pico 400 pump by pulling straight down on the pump from the inlet part 2.  
 
3)  See the next page for pump disassembly images to assist in taking them apart. Remove the airline by 

 pulling away from the powerhead.  During disassembly, ensure that no pieces are misplaced.  The Pico 400 
pump includes a small clear translucent bushing that the impeller rod fits into (inside red cap) and is 
required for quiet operation.  It can pop out, so please be careful during disassembly. 

 
4)  Wash all parts under warm tap water.  Do not use any detergents.  Make sure that the air line is clear of 
 

any foreign matter, calcium buildup or salt creep before reassembling. 

 
5)  Place the powerheads back in place on your 

AeroForce 2

TM

 

 

8)  Plug in the feed pump (9) first.  Once the skimmer pump becomes submerged, plug in the skimmer pump (8). 
 

 

Your AeroForce 2

TM

  is now operational.   

 
9)  Place the collection cup (1) in the skimmer column of the unit.  

The base of the collection funnel should be 1/8” 

 

below the water surface for optimal performance.  Slide the O-ring (2) up or down until the desired skimmate wet-

ness is achieved. 

 

 
 
It is common that some of the micro-bubbles escape to the tank during the initial set up.  The surface tension may rise 
due to the oils on the acrylic, additives and/or water conditioners being introduced to the water. The skimmer may pro-
duce excess bubbles until it is able to break down whatever is raising the surface tension of the water. This process can 
take from a few days to a number of weeks to clear completely

 

Summary of Contents for AeroForce 2

Page 1: ...Feed the power cord from the Ario4 through the center of the o ring Connect the airline to the pump Insert the base plate with the attached Ario4 pump 8 pg 4 diagram to the inside skimmer body by using the o ring to hold into position Insert the base plate from the bottom of the inner skimmer body 3 and stretch the o ring to hold onto the support bars 10 on the sides of the opening Pull the slack ...

Page 2: ...peller rod fits into inside red cap and is required for quiet operation It can pop out so please be careful during disassembly 4 Wash all parts under warm tap water Do not use any detergents Make sure that the air line is clear of any foreign matter calcium buildup or salt creep before reassembling 5 Place the powerheads back in place on your AeroForce 2TM 8 Plug in the feed pump 9 first Once the ...

Page 3: ... often contain conditioners which increase the surface tension of the water Bubbles should disappear within 48 hours The air line is clogged with detritus or salt creep This will increase the water flow rate and possibly sweep the bubbles from the skimmer chamber back into the tank before they can dissipate The airline should be cleaned every two weeks No waste collecting in collection cup The pow...

Page 4: ...are glued together and cannot be sepa rated New pumps will need to be purchased with base plate Pico 400 9 Collection cup Inlet part 2 Support pin 12 Outlet Inner body slides into outer body as shown Ensure that the Inlet part 1 and Inlet part 2 are in line with each other so that water can pass through both inlet parts Inner body 3 Outer body 4 ...

Reviews: