background image

TROUBLE SHOOTING 

Before calling CPR’s Technical Support, please take some time to look over this trouble  

shooting guide.  Most of the problems associated with the performance of the  

AeroForce 2

TM

 

are due to improper maintenance of the pumps.   

Cleaning the powerhead at least once a month will ensure  

optimal performance of the 

Aero Force

TM

  

 

Pico 400 disassembly 

disassembly 

Problem: 

Cause and Solution:

 

Small air bubbles returning to the tank 

The surface tension of the water has been increased by added supplements, medications,  
or conditioners.  Disable the protein skimmer by submerging the airline into the water 
(remove muffler first) or shutting off the air valve for 24 hours.  Many products contain 
chemicals which will still be present in the aquarium after 24 hours.  Run the protein 
skimmer as normal to remove compounds which may be affecting surface tension. 

 

The salinity is too high.  Lower the salinity to 1.023. 

 

Adjust the red flow controller on the feed pump.  Reducing the flow will slow the flow 
rate through the skimmer, reducing the draft of bubbles into the tank.  

 

The aquarium has just been cleaned or water has been changed.  Synthetic salt mixes 
often contain conditioners which increase the surface tension of the water.  Bubbles 
should disappear within 48 hours. 

 

The air line is clogged with detritus or salt creep.  This will increase the water flow rate 
and possibly sweep the bubbles from the skimmer chamber back into the tank before 
they can dissipate.  The airline should be cleaned every two weeks. 

No waste collecting in collection cup. 

The powerhead and its air line may be dirty.  Clean the whole unit every two weeks for 
optimal performance. 

 

The collection cup is not low enough.  See instructions for the correct height of the 
collection cup. 

 

The biological load may not be sufficient to generate waste.  On a new tank or a tank 
with supplemental filtration it may take over a week to generate waste foam. 

The Ario pump is producing little or no 
bubbles. 

The airline or the air control valve may be blocked.  Detritus, calcium and salt will build 
up in these parts over time.  Clean these parts every two to three weeks with warm tap 
water. 

 

The pump may need to be cleaned.  If the pump becomes clogged with organic material 
the flow rate and the air intake rates will reduce.  Follow the instructions included with 
your 

AeroForce 2

TM

 

to clean your pump.  

* a small, clear, translucent bushing is located inside of the red cap.  It can         

pop out during disassembly, so be careful to not misplace that required part.   

Summary of Contents for AeroForce 2

Page 1: ...Feed the power cord from the Ario4 through the center of the o ring Connect the airline to the pump Insert the base plate with the attached Ario4 pump 8 pg 4 diagram to the inside skimmer body by using the o ring to hold into position Insert the base plate from the bottom of the inner skimmer body 3 and stretch the o ring to hold onto the support bars 10 on the sides of the opening Pull the slack ...

Page 2: ...peller rod fits into inside red cap and is required for quiet operation It can pop out so please be careful during disassembly 4 Wash all parts under warm tap water Do not use any detergents Make sure that the air line is clear of any foreign matter calcium buildup or salt creep before reassembling 5 Place the powerheads back in place on your AeroForce 2TM 8 Plug in the feed pump 9 first Once the ...

Page 3: ... often contain conditioners which increase the surface tension of the water Bubbles should disappear within 48 hours The air line is clogged with detritus or salt creep This will increase the water flow rate and possibly sweep the bubbles from the skimmer chamber back into the tank before they can dissipate The airline should be cleaned every two weeks No waste collecting in collection cup The pow...

Page 4: ...are glued together and cannot be sepa rated New pumps will need to be purchased with base plate Pico 400 9 Collection cup Inlet part 2 Support pin 12 Outlet Inner body slides into outer body as shown Ensure that the Inlet part 1 and Inlet part 2 are in line with each other so that water can pass through both inlet parts Inner body 3 Outer body 4 ...