background image

CPR Aquatic, INC•P.O. Box 1111•3749 West End Road, Arcata, CA 95521 

CPR Technical Support (707) 826-9636 • FAX (707) 826-9623 

www.cprusa.com • cpr@cprusa.com 

CS90     

Continuous Siphon Overflow 

CPR’s Continuous Siphon Overflows provide the most efficient means of getting water to an external 
filter without expensive modifications to the tank.  These precision-engineered overflows skim water from 
the surface of your aquarium at flow rates up to six times greater than units with tubes.   Advantages 
such as water level adjustment, quiet operation, grated overflow, and a black top to reduce algae growth 
all make the CPR Continuous Siphon Overflow the best on the market.  Please read through the set up 
directions before and during the actual set up to ensure it is done correctly. 
 
To place your overflow into operation: 
 
1.  Open the packaging carefully and inspect the unit for damaged or missing parts.  You should have: 

(1) Overflow body 
(1)  Screen and sponge 
(1)  Vent tube with small “O” ring 
(1) Bulkhead assembly  
(3) Adjustment screws 
(1) Air line 
(1)  Aqua Lifter pump and Acrylic Lid (included in Deluxe models) 

If any items are damaged or missing, please contact your dealer immediately. 
 
2.  Before using the overflow for the first time it is important to decide where to position the unit.  It is 

best to have the overflow as far away from the inflow as possible to reduce turbulence.  It is also 
important to check the capacity of your sump as well as the flow rate of your return pump on your 
filtration system to prevent possible overflow.  It will be necessary to add water to the system after 
it begins running.  The amount of water that you will need to add will depend on the sump size and 
design. 
 

3.  Assemble the bulkhead fitting as shown in diagram A.  Insert the pre-filter screen into the bulkhead 

and place the pre-filter sponge over the screen.  Insert the vent tube into the hole at the top of the 
pre-filter screen.  The “O” ring can slide up or down to adjust the height of the vent tube once the 
unit is operational. 

4.  Connect the bulkhead fitting to the hose going into your filtration system.  You should use 1” 

Schedule 40 PVC inserted into the slip fitting inside the bulkhead.  The PVC can be run directly into 
the filter or can be attached to 1 1/4” flexible line (using the optional PVC adapter available at Ameka 
Aquatics.com).  The fewest bends in the line will ensure the quietest operation.  To prevent leakage 
from where the PVC inserts into the bulkhead, you should use PVC cement to secure it into place.   If 
using adapters other than PVC, All-Purpose Cement should be used to secure the plumbing in place. 

 
5.  Place the unit on the edge of your tank and allow the water to fill the front chamber.  Adjust the 

lower adjustment screws so that the unit is parallel to the back of the tank. 

 

Reviews: