PART NO.
BP2592-00-0001
SERIAL NUMBER
TITLE
INSTRUCTION MANUAL - BP2592
7313 SW TECH CENTER DRIVE
PORTLAND, OR 97223 USA
PH: (503) 598-9595 FAX: (503) 682-8164
WWW.CPSHV.COM
SHEET
6
REV
A
SPECIFICATION NO.
BP2592-89-0001
FSCM NO.
31640
SIZE
A
WARNING
Replacement of internal fuse must be performed by qualified personnel. Contact manufacturer
for instructions.
6. Block Diagram:
Fig. 1. Block diagram of BP2592 high voltage power supply
7. Environmental Conditions:
Model BP2592 must operate under following conditions:
-
the equipment is intended for indoor use only;
-
operating temperature 0 to 50
0
C;
-
altitude up to 1000 m;
-
maximum relative humidity 80% at 31
0
C and 50% at 40
0
C
-
installation Category - Intended for use in installation category (overvoltage category) II
(IEC 1010-1 standard).
-
Pollution Degree - Category 2 (IEC 1010-1 standard)
8. Mechanical Specifications:
Output mating connector:
CPS part number 1314-06-0001 with screened cable
AC to DC
Converter
Bipolar HV
Power Supply
Splitter Box with
2M
Ω
softening
resistors
Output Voltage
Program Pot with
On Off Switch
Output Voltage
Display
AC Input
HV Output
On Off
Switch
Polarity
Select
Switch