3

• Replaceable or cleanable filter cartridge.

• The Suction and Discharge shut-off valves.  Easy to service if replacement required.

• Heavy-duty powder coated aluminum chassis surrounded by a tough High-Density Polyethylene case.

• Maintenance free Oil-less compressor

• Optional tank overfill sensor cord kit.

• patent pending

Low Pressure override switch to allow for continous operaton. To help you get a good start, please continue

to carefully read the balance of this manual. This manual contains important information on the proper

procedures for operating this equipment. Please pay close attention to the safety information, WARNING

and CAUTIONS provided throughout this manual. Always remember “SAFETY FIRST”.

GENERAL SAFETY INSTRUCTIONS

Only qualified service personnel should operate this unit.  Most states, countries, etc… may require the 

user to be licensed.  Please check with your local government agency.

DANGER

- the recovery tank used with this contains liquid refrigerant.  Overfilling of the recovery tank may 

cause a violent explosion resulting in severe injury or even death.  As a minimum, please use a scale to 

continuously monitor the recovery tank weight.

DANGER

- Avoid breathing refrigerant vapors and lubricant vapor or mist.  Breathing high concentration 

levels may cause heart arrhythmia, loss of consciousness, or even cause suffocation.  

DANGER

- ELECTRICAL SHOCK HAZARD-Always disconnect power source when servicing this equipment. 

DANGER

- EXPLOSION RISK.  Do not recovery flammable refrigerants

CAUTION-

all hoses may contain liquid refrigerant under pressure.  Contact with refrigerant may cause 

frostbite or other related injuries.  Wear proper personal protective equipment such as safety goggles and 

gloves.  When disconnecting any hose, please use extreme caution.

CAUTION-

avoid breathing refrigerant vapors and/or lubricant mist.  Exposure may irritate eyes, nose, 

throat, and skin.  Please read the manufacturers Material Safety Data Sheet for further safety information on 

refrigerants and lubricants.

CAUTION-

to reduce the risk of fire, avoid the use of extension cords thinner than NO. 14 awg. (1,5mm) to 

prevent the overheating of this cord please keep length to a minimum.

CAUTION-

do not use this equipment in the vicinity of spilled or open containers of gasoline or other 

flammable substances.  Make certain that all safety devices are functioning properly before operating the 

equipment.

This equipment is intended for use of one refrigerant at a time until the Self-Clearing feature is used. Mixing 

of different refrigerants will cause your recovered supply of refrigerant to become contaminated.

Note:  It is very expensive to destroy mixed or damaged refrigerants. 

Summary of Contents for PRO-SET CR700 Series

Page 1: ...EL ONLY 1 HP Commercial Refrigerant Recovery System OPERATION MANUAL TABLE OF CONTENTS Specifications Introduction General Safety Instructions Direct Liquid or Vapor Recovery Operation Liquid Push Pull Operation Routine Maintenance 2 2 3 3 4 4 5 ENGLISH 1 5 ...

Page 2: ...harge gauge to handle R 410A Small physical size Automatic Low Pressure cutout switch Integrated easy to use carrying handle and Safety bar 550 psig High Pressure cutout switch Easy and secure filter accesses No dangling filters to be damaged Models Compressor Type Dimensions Weight Operating Temperature Range Power Source Power Consumption Suction Pressure Gauge Discharge Pressure Gauge Filtratio...

Page 3: ...athing high concentration levels may cause heart arrhythmia loss of consciousness or even cause suffocation DANGER ELECTRICAL SHOCK HAZARD Always disconnect power source when servicing this equipment DANGER EXPLOSION RISK Do not recovery flammable refrigerants CAUTION all hoses may contain liquid refrigerant under pressure Contact with refrigerant may cause frostbite or other related injuries Wear...

Page 4: ...CLEARING position The CR700 will resume operation automatically The CR700 is now clearing out the condensor The CR700 will automatically shut off when a 10 hg vacuum is achieved Note If the LP override switch is set to ON position the unit will run continuously RECOVERY AND SELF CLEARING ARE COMPLETE LIQUID PUSH PULL OPERATION 1 Connect the unit as shown in Diagram 2 Note The recovery tank must be...

Page 5: ...ure 1 Once loose remove the suction port filter cartridge as shown in Figure 2 Either clean the current cartridge or replace with new cartridge Inspect O ring Re lubricate with compressor oil or equivalent Place filter cartridge back into suction port fitting Hand tighten this assembly back onto the CR700 Use a 5 8 socket or boxed end wrench to tighten 1 8 of a turn Do not over tighten damage to t...

Reviews: